MIL-STD-202H.pdf - 第182页

MI L - S TD - 202 -2 11 STEP 1. Bend l ead with finger s, ov er r o unded edg e of m et al plat e as shown in ( a). STEP 2. Center component p art i n c hu c k ; s e c ur e l ea d in clamp as shown in (b). STEP 3. Rotate…

100%1 / 305
MIL-STD-202-211
FIGURE 2. Test condition B.
FIGURE 3. Test condition C.
4
北测(上海)电子科技有限公
联系方式:xuyj@beice-sh.com 13917165676
MIL-STD-202-211
STEP 1. Bend lead with fingers, over rounded edge of metal plate as shown in (a).
STEP 2. Center component part in chuck; secure lead in clamp as shown in (b).
STEP 3. Rotate chuck part through 360° at a rate of approximately 5 seconds per 360° rotation. Successive
rotations shall be in alternate directions. A total of three such 360° rotations shall be performed. During
this test, the chuck shall rotate around an axis which is fixed with respect to the padded clamp, or vice
versa. The chuck shall have no appreciable end play during rotation.
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are in parentheses and are given for general information only.
FIGURE 4. Test condition D.
5
北测(上海)电子科技有限公
联系方式:xuyj@beice-sh.com 13917165676
MIL-STD-202-211
FIGURE 5. Test condition E.
NOTE: Equivalent diameter is twice the distance between the lines indicated by the arrows.
FIGURE 6. Method of determining equivalent diameter.
6
北测(上海)电子科技有限公
联系方式:xuyj@beice-sh.com 13917165676