MIL-STD-202H.pdf - 第183页
MI L - S TD - 202 -2 11 F I G URE 5 . T es t c ond i t i o n E . NOT E: E qui v al ent d i am eter is tw ice the distan ce between th e lines indica ted by the arr ows. F IGURE 6. Method of d etermining equivalent dia me…

MIL-STD-202-211
STEP 1. Bend lead with fingers, over rounded edge of metal plate as shown in (a).
STEP 2. Center component part in chuck; secure lead in clamp as shown in (b).
STEP 3. Rotate chuck part through 360° at a rate of approximately 5 seconds per 360° rotation. Successive
rotations shall be in alternate directions. A total of three such 360° rotations shall be performed. During
this test, the chuck shall rotate around an axis which is fixed with respect to the padded clamp, or vice
versa. The chuck shall have no appreciable end play during rotation.
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are in parentheses and are given for general information only.
FIGURE 4. Test condition D.
5
北测(上海)电子科技有限公司
联系方式:xuyj@beice-sh.com 13917165676

MIL-STD-202-211
FIGURE 5. Test condition E.
NOTE: Equivalent diameter is twice the distance between the lines indicated by the arrows.
FIGURE 6. Method of determining equivalent diameter.
6
北测(上海)电子科技有限公司
联系方式:xuyj@beice-sh.com 13917165676

MIL-STD-202-211
5. DETAILED REQUIREMENTS
5.1 Measurements. Measurements to be made before and after the test, as applicable, shall be as specified in the
individual specification.
5.2 Summary. The following details are to be specified in the individual specification:
a. Test condition letter(s) (see 4.2).
b. If test condition letter A is specified:
(1) If pertinent, the method of holding or clamping (see 4.2.1.1).
(2) Whether applied force shall be 1/2, 1, 2, 3, 5, 10, or 20 pounds (see 4.2.1.2).
c. If test condition letter B is specified:
(1) If critical, the method of bending and fixture required (see 4.2.2.2).
(2) Whether number of bends shall be 2 or 5 (see 4.2.2.3).
d. If test condition letter C is specified:
(1) Whether the load shall be 1/4, 1/2, 1, 5, or 10 pounds (see 4.2.3.1).
e. If test condition letter E is specified:
(1) Torque to be applied to non-wire, rigid-type terminals when equivalent diameter is
greater than 1/2 inch (see 4.2.5.4).
f. Measurements before and after test, as applicable (see 5.1).
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Supersession data. The main body and 38 parts of this revision of MIL-STD-202 replace superseded MIL-STD-
202.
Custodians: Preparing activity:
Army - CR DLA – CC
Navy - EC
Air Force - 85 (Project 59GP-2015-025)
DLA - CC
Review activities:
Army - AR, AT, AV, CR4, MI, SM, TE
Navy - AS, OS, SH
Air Force - 19, 99
NSA - NS
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.dla.mil/