MIL-STD-202H.pdf - 第47页

MI L - S TD - 202 - 107 T ABL E I . T her m al s ho c k t es t c ond i t i o ns ( ai r ) 1 / . Te st co ndit ion N um ber of cy cl e s Te s t c o n di t i on N um ber of cy cl e s T est c o n dit ion Number of cycle s St…

100%1 / 305
MIL-STD-202-107
4.2. PROCEDURE.
4.2.1 Environmental chambers. Specimens shall be placed so that there is substantially no obstruction to the flow
of air across and around the specimen. When special mounting is required, it shall be specified. The specimen shall
be subjected to the specified test condition of table I. The first five cycles shall be run continuously. After five cycles,
the test may be interrupted after the completion of any full cycle, and the specimens allowed to return to room
ambient temperature before testing is resumed. One cycle consists of steps 1 through 4 of the applicable test
condition. Specimens shall not be subjected to forced circulating air while being transferred from one chamber to
another. Whether single or multiple chambers are used, the effective total transfer time from the specified low
temperature to the specified high temperature, or the reverse, shall not exceed 5 minutes. Direct heat conduction to
the specimen should be minimized. In the case of multiple chambers, the transfer time shall be defined as the time
between withdrawal from the low temperature chamber and introduction into the high temperature chamber or the
reverse.
NOTE: In single compartment chambers, in which the temperature extremes of steps 1 and 3 are achieved without
physical movement of the specimens, steps 2 and 4 are not applicable.
4.2.2 Liquid baths. Specimens shall be immersed in a suitable liquid that shall be approved by the qualifying
activity (see table IV), at the temperature in step 1 of the specified test condition (see table III) for the time specified in
table V. Immediately upon the conclusion of step 1, the device shall be transferred to a suitable liquid at the
temperature specified in step 2 of the specified test condition. The device shall remain at the high temperature for the
time specified in table V. These two steps, step 1 and 2, constitute one cycle of the applicable test condition. Repeat
the required number of cycles without interruption as specified in table III. Transfer time from low to high temperature
and from high to low temperature shall be less than 10 seconds.
4.3 Measurements. Specified measurements shall be made prior to the first cycle and upon completion of the final
cycle, except that failures shall be based on measurements made after the specimen has stabilized at room
temperature following the final cycle.
5. DETAILED REQUIREMENTS
5.1. Summary. The following details are to be specified in the individual specification:
a. Recovery time if other than 5 minutes (see 4.1.1).
b. Special mounting, if applicable (see 4.2).
c. Type test (air or liquid) and test condition (see 4.2).
d. Transfer time if other than specified in 4.2.1 or 4.2.2.
e. Measurements before and after cycling (see 4.3).
2
北测(上海)电子科技有限公
联系方式:xuyj@beice-sh.com 13917165676
MIL-STD-202-107
TABLE I. Thermal shock test conditions (air) 1/.
Test
condition
Number of
cycles
Test
condition
Number of
cycles
Test
condition
Number of
cycles
Step A 5 B 5 C 5
A-1 25 B-1 25 C-1 25
A-2 50 B-2 50 C-2 50
A-3 100 B-3 100 C-3 100
Temperature Time Temperature Time Temperature Time
1
2
3
4
°C
-55 +0, -3
25 +10, -5
85 +3, -0
25 +10, -5
See table II
5 minutes
maximum
°C
-65 +0, -5
25 +10, -5
125 +3, -0
25 +10, -5
See table II
5 minutes
maximum
°C
-65 +0, -5
25 +10, -5
200 +5, -0
25 +10, -5
See table II
5 minutes
maximum
Test
condition
Number of
cycles
Test
condition
Number of
cycles
Test
condition
Number of
cycles
Step D 5 E 5 F 5
D-1 25 E-1 25 F-1 25
D-2 50 E-2 50 F-2 50
D-3 100 E-3 100 F-3 100
Temperature Time Temperature Time Temperature Time
1
2
3
4
°C
-65 +0, -5
25 +10, -5
350 +5, -0
25 +10, -5
See table II
5 minutes
maximum
°C
-65 +0, -5
25 +10, -5
500 +5, -0
25 +10, -5
See table II
5 minutes
maximum
°C
-65 +0, -5
25 +10, -5
150 +3, -0
25 +10, -5
See table II
5 minutes
maximum
1/ When method 102, condition A, B or D has been specified use condition A.
When method 102, condition C has been specified use condition B
TABLE II. Exposure time in air at temperature extremes.
Weight of specimen
Minimum time
(for steps 1 and 3)
1 ounce (28 grams and below)
Above 1 ounce (28 grams) to .3 pound (136 grams), inclusive
Above .3 pounds (136 grams) to 3 pounds (1.36 kilograms), inclusive
Above 3 pounds (1.36 kilograms) to 30 pounds (13.6 kilograms), inclusive
Above 30 pounds (13.6 kilograms) to 300 pounds (136 kilograms), inclusive
Above 300 pounds (136 kilograms)
Hours
1/4 (or as specified)
½
1
2
4
8
3
北测(上海)电子科技有限公
联系方式:xuyj@beice-sh.com 13917165676
MIL-STD-202-107
TABLE III. Thermal shock conditions (liquid).
Test
condition
Number
of cycles
Test
condition
Number
of cycles
Test
condition
Number
of cycles
Test
condition
Number
of cycles
Step AA 5 BB 5 CC 5 DD 5
AA-1 15 BB-1 15 CC-1 15 DD-1 15
AA-2 25 BB-2 25 CC-2 25 DD-2 25
Temperature Time Temperature Time Temperature Time Temperature Time
1
2
°C
-0 +2, -10
100 +10, -2
See
table V
°C
-65 +0, -10
125 +10, -0
See
table V
°C
-65 +0, -10
150 +10, -0
See
table V
°C
-65 +0, -10
200 +10, -0
See
table V
TABLE IV. Suggested thermal fluids. 1/ 2/
Test
condition
AA, AA-1, AA-2
fluids
BB, BB-1, BB-2
Fluids
CC, CC-1, CC-2
fluids
DD, DD-1, DD-2
fluids
Step 1 FC40 4/ or
Water 3/
FC77 4/ FC77 4/ FC77 4/
D02
D02-TS 6/
D/80
D02
D02-TS 6/
D/80
D02
D02-TS 6/
D/80
D02
D02-TS 6/
D/80
Step 2 FC40 4/
Water 3/
FC70
FC40 4/
FC70
FC40 4/
FC70 4/
UCON-WS 5/
UCON-WS 5/
UCON-WS} 5/
D02
D02-TS 6/
D03
D02
D02-TS 6/
D03
D02
D02-TS 6/
D03
D05
LS/230 6/
LS/215
1/ See 4.2.2.
2/ Ethylene glycol shall not be used as a thermal shock test fluid.
3/ Tap water is indicated as an acceptable fluid for this temperature range. Its suitability chemically shall be
established prior to use. A mixture of water and alcohol may be used to prevent freezing at the low
temperature extreme. The water shall not be allowed to boil at the upper temperature extreme.
4/ FC77, FC70, FC40 are the registered trademark of 3M.
5/ UCON-WS process fluid is the registered trademark of Union Carbide Corporation.
6/ D02, D02-TS, D03, D05, D/80, LS/215 and LS/230 are the registered trademark of Ausimont (Division of
Montedison).