MIL-STD-202H.pdf - 第217页
MI L - S TD - 202 -2 1 5 6. NOTES (This secti on contain s i n f or m at i on o f a g ener al or ex pl anat or y nat ur e t ha t m ay be he l pf ul , b u t is not mandatory .) 6.1 Supers ession data . T he m ai n b ody a…

MIL-STD-202-215
TABLE I. Summary table for resistance to solvents.
Solvent 1 Solvent 2 Solvent 3 Solvent 4
1 part (by volume) of isopropyl
alcohol (ACS)
reagent grade or TT-I-735,
grade A or B and 3 parts (by
volume) of mineral spirits per
MIL-PRF-680, type I,
or three parts (by volume) of a
mixture of 80% (by volume) of
kerosene and 20%
(by volume) ethylbenzene.
This solvent has
been deleted.
Terpene defluxer
42 parts (by volume) of
water
1 part (by volume) of
propylene glycol
monomethyl ether
1 part (by volume) of
monoethanolamine
Immersion 3 +.5, -0 minutes,
25°C ±5°C
Immersion 3 +.5, -0
minutes, 25°C, ±5°C
Immersion 3 +.5, -0
minutes, 63°C to 70°C
Brush 10 strokes (wet bristle)
2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Immersion 3 +.5, -0 minutes,
25°C ±5°C.
Immersion 3 +.5, -0
minutes, 25°C ±5°C.
Immersion 3 +.5, -0
minutes, 63°C to 70°C.
Brush 10 strokes (wet bristle)
2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Immersion 3 +.5, -0 minutes,
25°C ±5°C.
Immersion 3 +.5, -0
minutes, 25°C ±5°C.
Immersion 3 +.5, -0
minutes, 63°C to 70°C.
Brush 10 strokes (wet bristle)
2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Brush 10 strokes (wet
bristle) 2 to 3 oz.
Rinse in water
Rinse in water.
Air blow dry.
Air blow dry
Air blow dry.
Inspect at 3X maximum for
marking.
Inspect at 10X maximum for
part damage.
Inspect at 3X maximum
for marking.
Inspect at 10X maximum
for part damage.
Inspect at 3X maximum
for marking.
Inspect at 10X maximum
for part damage.
5
北测(上海)电子科技有限公司
联系方式:xuyj@beice-sh.com 13917165676

MIL-STD-202-215
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Supersession data. The main body and 38 parts of this revision of MIL-STD-202 replace superseded MIL-STD-
202.
Custodians: Preparing activity:
Army - CR DLA – CC
Navy - EC
Air Force - 85 (Project 59GP-2015-029)
DLA - CC
Review activities:
Army - AR, AT, AV, CR4, MI, SM, TE
Navy - AS, OS, SH
Air Force - 19, 99
NSA - NS
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.dla.mil/
6
北测(上海)电子科技有限公司
联系方式:xuyj@beice-sh.com 13917165676

MIL-STD-202G
w/CHANGE 2
1
METHOD 216
RESISTANCE TO SOLDER WAVE HEAT
NOTICE
Method 216 has been canceled effective 16 April 1973. Use the test conditions in method 210 in lieu of the test
conditions of method 216. Use the table below for the applicable cross reference.
When method 216
is specified
Use method 210
Test condition A
Test condition B
Test condition C
Test condition C
Test condition D
Test condition E
METHOD 216
16 April 1973
北测(上海)电子科技有限公司
联系方式:xuyj@beice-sh.com 13917165676