FCM_User Reference Manual.pdf.pdf - 第108页

MIS User Re ference Manual 4022 5 91 96082 5-16 F CM Mult ifl ex 02.02 fcm05 19a.tif SCREE N 5-1 2 [Proc ess r eport... ] screen ex am p le, part 2 ✱✱ Detailed Inf ormation ▼ Dis played Info rmatio n The [Pr ocess r epo …

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-15
MIS
5.3.2.4 [Reports] > [Process report...]
TABLE 5-5 Quick Reference
fcm0518a.tif
SCREEN 5-11 [Process report...] screen example, part 1
Actions select [Functions...] in the MIS pull-down menu
select [Reports]
select [Process report...]
Conditions order active
Information FCM Multiflex machine identification and serial no.
MIS period name + start/stop date/time
action spec name
order name
report date/time
number of auto retries per placement module + per
feeder
number of manual retries per placement module +
per feeder
number of picked SMDs per placement module + per
feeder
number of not placed SMDs (skipped) per placement
module + per feeder
misalign details per placement module + per feeder
retry limit
time lost due to process errors
Display Options process report for all modules
process report per placement module
(zoom-in function)
see next screen
MIS
User Reference Manual 4022 591 96082
5-16 FCM Multiflex 02.02
fcm0519a.tif
SCREEN 5-12 [Process report...] screen example, part 2
✱✱ Detailed Information
Displayed Information
The [Process report...] report gives a textual overview of the process errors.
They can either be displayed for all placement modules or for a specific
placement module.
On first entry, the report displays an overview on all (used) placement modules
(see 5.3.2.5 and SCREEN 5-12).
The process errors are divided into auto retries and manual retries
(see SCREEN 5-13).
fcm0516a.tif
SCREEN 5-13
see previous screen
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-17
MIS
An auto retry is a retry without operator intervention (automatic); the
maximum allowed number of auto retries is determined in the action spec,
see SCREEN 5-13.
A manual retry is a retry by operator intervention. After the FCM Multiflex
has reached the auto retry number limit, it stops, and manual retries may be
done by the operator then. Note that only those manual retries are taken
into account for the
[Process report...] report that were successful at first
attempt.
fcm0517a.eps
SCREEN 5-14 Action spec setting of the maximum number of auto pick retries (refires)
FEEDER 1 1 T8-M/4 T 333-222-112 SOD-80
COMMENT index coordinates are relative to pipette origin
COMMENT indx/brd /refholex/refholey/board_x /board_y
INDEX 1 3 -75.500 294.250 -81.500 138.000
INDEX 1 4 74.500 294.250 68.500 138.000
INDEX 2 3 4.500 294.250 -1.500 138.000
COMMENT pick coordinates are relative to pipette origin
COMMENT fd/pk/psh/rfr/pick_x /pick_y /pick_phi/na/prf/arf/ale/ple
PICK 1 1 1 2 19.000 77.000 90.0 1 75 55 80 80
COMMENT: In case a deviating dump position is needed enter
COMMENT: DUMP position_x position_y
COMMENT mount coordinates are in board coordinates
in this example, the number of auto(matic)
pick retries (or
refires
) is set to 2
rfr = refires