4022 591 960 82 Us er Reference Man ual 02.02 FC M Multif lex 6-21 Pr oduc t Ch ang e Ov er NOTE: We advise to set th is parameter to “ 1” . SCREEN 6- 12 A utomatic teac hing Th e n ex t par am et er s in th e l ist bo x…

Product Change Over
User Reference Manual 4022 591 96082
6-20 FCM Multiflex 02.02
Tolerance
■ Select [Tolerance]
The value set here determines how much the area of a detected fiducial may
differ from the area which is specified in the teach data (see FIGURE 6 -9)
That area is defined by the
[Area of Fiducial] parameter, and limited by the
[Smallest Enclosing Rectangle] setting.
SCREEN 6-11
NOTE: Common settings range from 10 to 15% on good fiducials; fiducials of less
quality may require a higher value.
FIGURE 6-9 Tolerance between taught and detected fiducial area
Number Of Retries
■ Select [Number Of Retries]
Refers to the number of retries which are allowed when performing a test meas-
urement of a fiducial.

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-21
Product Change Over
NOTE: We advise to set this parameter to “ 1” .
SCREEN 6-12
Automatic teaching
The next parameters in the list box are green. These settings can be taught auto-
matically by selecting [Teach]. After the settings are taught the results are
presented in the [Teach Fiducial/Badmark Results] dialogue screen.
SCREEN 6-13
In this screen the current and the new (taught) settings for Light Level, Threshold
and Area are shown for both algorithms. By deactivating the checkboxes the current
settings will be used else the new settings will be used. The Confidence level
indicates which algorithm is most suitable for that fiducial. In [Select Algorithm]

Product Change Over
User Reference Manual 4022 591 96082
6-22 FCM Multiflex 02.02
you can change the algorithm, the one with the highest Confidence Level is
preferred. Select [Ok] to set the new settings or [Cancel] to discard the new
settings.
The results of the automatic teaching can be tested by selecting [Measure].
■ Select
[Teach]
■ Select [Measure]
The test results of the measurement will be shown in the box.
NOTE: Normally the automatic teach function will supply the correct values!
!
WARNING: IF FIRST TEACHING DOESN’T GET THE FIDUCIAL IN THE CENTRE OF THE
SCREEN, FIRST CHECK THE CORRECTNESS OF THE CARRIER SET MOUNTING
(WELL FASTENED? NO CLEARANCE?) AND/OR THE ACTION SPEC FIDUCIAL
COORDINATES CONCERNED.
■ Select [Store] to store the taught data in the current data base
■ Select
[Next Fiducial] to go to the next fiducial to be measured
■ Select
[Type...] to change the type of fiducial to be taught
Light Level and Threshold
■ Select [Light Level and Threshold]
For a reliable fiducial detection, the light level and threshold must have been
set.
The threshold value is used by the binary algorithm to transform a grey level
image into a black & white image.
The threshold value is used by the interpolation algorithm to analyze grey level
transitions in the image.
SCREEN 6-14