FCM_User Reference Manual.pdf.pdf - 第157页
4022 591 96082 User Re ference Manual 02.02 FCM Multiflex 5-65 MIS Er ro r co de Subsystem Error descripti on 41014 TC Unexpected boar d in r unout - remove 41015 Init restart needed 41016 Stopper run-out does not w or k…

MIS
User Reference Manual 4022 591 96082
5-64 FCM Multiflex 02.02
Error code Subsystem Error description
40974 TC Error on HOIST movement: Motor Off
40975 Unknown error (TC AST15)
40976 Unknown error (TC AST16)
40977 Homing error BEAM: no right stop
40978 Homing error HOIST: no up stop
40979 Unknown error (TC AST19)
40980 Unknown error (TC AST20)
40981 Homing error BEAM: Pulse not found
40982 Homing error HOIST: Pulse not foun
40983 Unknown error (TC AST23)
40984 Unknown error (TC AST24)
40985 Homing error BEAM: no left stop
40986 Homing error HOIST: no down stop
40987 Unknown error (TC AST27)
40988 Unknown error (TC AST28)
40989 Homing error BEAM: move obstructed
40990 Homing error HOIST: move obstructe
40991 Unknown error (TC AST31)
40992 Unknown error (TC AST32)
40993 Board stuck in run-in section
40994 Timeout on HOIST movement
40995 Board stuck in run-out section
40996 Centering board in run-in failed
40997 Requested BEAM pos. out of range
40998 Requested HOIST pos. out of range
40999 Stopper run-in front does not work
41000 Stopper run-in rear does not work
41001 Unexpected board in run-in section
41002 No actionspec. available
41003 Index number out of range
41004 No command available ( do_step)
41005 SMEMA runout blocked
41006 Bad or suspected board in run-out
41007 Board missing in run-out section
41008 Transport not homed yet
41009 Requested func. can’t be performed
41010 Continuation not possible: restart
41011 TC lost location of boards
41012 Servo amplifiers disabled
41013 Unexpected board in runin - remove

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-65
MIS
Error code Subsystem Error description
41014 TC Unexpected board in runout - remove
41015 Init restart needed
41016 Stopper run-out does not work
41017 Error during erase flash PROM
41018 Flash PROM write protected
41019 Flash PROM full or defect
41020 Unknown error (TC AST60)
41021 Unknown error (TC AST61)
41022 Unknown error (TC AST62)
41023 Unknown error (TC AST63)
41024 Unknown error (TC AST64)
44032 LAS miss SMD after pick
44033 retain SMD after place
44034 lost SMD after align
44035 Vacuum level wrong
44036 Req X pos out of range
44037 Req Y pos out of range
44038 Req Phi pos out of range
44039 Power dip during MUP down
44040 Servo tracking err X axis
44041 Servo tracking err Y axis
44042 Servo tracking err Phi axis
44043 Servo power failure
44044 MUP/pusher down during move
44045 Undefined Error (LAS-26)
44046 Move when servo amp. disabled
44047 Move req while no homing done
44048 Zero EPD not found X axis
44049 Zero EPD not found Y axisd
44050 Zero EPD not found Phi axis
44051 Pusher down during move
44052 Index pulse X axis not found
44053 Index pulse Y axis not found
44054 Index pulse Phi axis not found
44055 PPU communication error
44056 Left stop X axis not found
44057 Front stop Y axis not found
44058 Home err Phi area too large
44060 X axis obstructed
44061 Y axis obstructed

MIS
User Reference Manual 4022 591 96082
5-66 FCM Multiflex 02.02
Error code Subsystem Error description
44062 LAS Home err Phi area too large
44064 Communication error on X servo
44065 Communication error on Y servo
44066 Communication err on Phi servo
44067 RS422 laser align link rcv. error
44068 Timeout communication X servo
44069 Timeout communication Y servo
44070 Timeout Communication Phi serv
44071 LAS RS422 laser align link xmit error
44072 Flash EPROM write protected
44073 Flash EPROM table full
44074 Suspected placement, check SMD
44075 Flash EPROM zero offsets lost
44076 Timeout Smart Feeder
44077 X pos out of range, offset/FFA
44078 Y pos out of range, offset/FFA
44079 misalign SMD
44080 MUP too slow
44081 MUP too fast
44082 PPU changed, associate?
44083 PPU changed, associate!
44084 Chuck not conform Action spec
44085 PPU cal. checksum error
44086 Laser sensor exchanged
44087 Data eeprom LA sensor corrupted
44088 X pos out of range due to LA comp.
44089 Y pos out of range due to LA comp.
44090 X pos out of range due to MUP comp
44091 Y pos out of range due to MUP comp
44092 X pos out of range due to XY comp.
44093 Y pos out of range due to XY comp.
44094 X pos out of range due to Pick off
44095 Y pos out of range due to Pick off
44096 X pick offset too large
44097 Y pick offset too large
44098 Phi pick offset too large
44099 SMD length not within req. limits
44100 SMD width not within req. limits
44101 SMD lost due to power down
44102 Align id not present (sys. error)