■ The process errors are divided into auto retries and manual retries (see below).
fcm0528a.tif
SCREEN 5-24
• An auto retry is a retry without operator intervention (automatic); the
maximum allowed number of auto retries is determined in the action spec,
(see SCREEN 5-25).
• A manual retry is a retry by operator intervention. After the FCM Multiflex
has reached the auto retry number limit, it stops, and manual retries may be
done by the operator then. Note that only those manual retries are taken
into account for the
[Process report...] report that were successful at first
attempt.
fcm0517a.eps
SCREEN 5-25 Action spec setting of the maximum number of auto pick retries (refires)
FEEDER 1 1 T8-M/4 T 333-222-112 SOD-80
COMMENT index coordinates are relative to pipette origin
COMMENT indx/brd /refholex/refholey/board_x /board_y
INDEX 1 3 -75.500 294.250 -81.500 138.000
INDEX 1 4 74.500 294.250 68.500 138.000
INDEX 2 3 4.500 294.250 -1.500 138.000
COMMENT pick coordinates are relative to pipette origin
COMMENT fd/pk/psh/rfr/pick_x /pick_y /pick_phi/na/prf/arf/ale/ple
PICK 1 1 1 2 19.000 77.000 90.0 1 75 55 80 80
COMMENT: In case a deviating dump position is needed enter
COMMENT: DUMP position_x position_y
COMMENT mount coordinates are in board coordinates
in this example, the number of auto(matic)
pick retries (or
refires
) is set to 2
rfr = refires

MIS
User Reference Manual 4022 591 96082
5-30 FCM Multiflex 02.02
Graph explanation, All modules, Averages option
fcm0527a/0529a.tif
SCREEN 5-26 [Process graph...] All modules, Averages screen examples
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used placement
modules
Placed scale for total number of placed SMDs
total number of placed SMDs per placement
module (blue circle)
Auto retries aft. pick total number of automatic pick retries per place-
ment module that occurred after SMD was
missing immediately after pick action
misalign total number of automatic pick retries per place-
ment module that occurred after SMD could not
properly be aligned
align total number of automatic pick retries per place-
ment module that occurred after SMD was
missing upon starting the align action (WVM
only)

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-31
MIS
TABLE 5-13
Graph legend Explanation
Manual pick err.
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per
placement module after SMD was missing
immediately after pick action
misalign
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per
placement module after SMD could not properly
be aligned
lost BA
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per
placement module after SMD was missing upon
starting the align action (WVM only)
lost AA
■ FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
■ total number of manual pick retries per
placement module
retained
■ FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying to
place it on the board
■ total number per placement module of manual
pick retries
skipped total number per placement module of picked
SMDs that are not placed (dumped) as a result of
selecting [Skip action] or [Skip board] in the
[Error Recovery] dialogue