FCM_User Reference Manual.pdf.pdf - 第79页

4022 591 96082 User Re ference Manual 02.02 FCM Multiflex 4-33 Mount Program syn t ax: feed er_pos _nr + pi ck_po s _nr + feed er_id + fe eder_ typ e + c omponent_id + package_id / smd_info_ file_id [+ feeder_phi [+ feed…

100%1 / 306
Mount Program
User Reference Manual 4022 591 96082
4-32 FCM Multiflex 02.02
Placement Module Activities (continued)
AS LAS/WVM 3
COMMENT
COMMENT Placement module actions for position 3
COMMENT
COMMENT PPU_id /nozzle_id /clow/chgh/cidx
MUP VISION 4900 20 50 1
BOARD_ROTATION 0
COMMENT index coordinates are relative to placement module origin
COMMENT indx /brd /refholex /refholey /board_x /board_y
INDEX 1 3 -7.000 143.500 269.000 138.000
INDEX 2 3 3.000 143.500 339.000 138.000
INDEX 3 2 -157.000 143.500 119.000 138.000
INDEX 4 2 -77.000 143.500 199.000 138.000
COMMENT feed/pick /feeder_id /type /component_id /smd info [/feeder_phi /f_pick_x /f_pick_y]
FEEDER 301 1 T12-P T 93697451 SO-8 0.0
FEEDER 303 1 T12-P T 93697711 SO-8 0.0
FEEDER 307 1 T12-P T 93697706 SO-8 0.0
FEEDER 401 1 T16-P T 286114465Z SO-16 0.0
FEEDER 404 1 T24-P T 286114414A VSOP.CA 0.0 0.2 0.1
COMMENT pick coordinates are relative to placement module origin
COMMENT fd /pk/psh/mrp/mra/pick_x /pick_y/pick_phi/na/prf/arf/ale/ple [/c_pick_x/c_pick_y]
PICK 301 1 1 1 0 19.000 77.000 90.0 1 50 28 80 80
PICK 303 1 1 1 0 51.000 77.000 90.0 1 50 28 80 80
PICK 307 1 1 1 0 99.000 77.000 90.0 1 50 28 80 80
PICK 401 1 1 1 0 187.000 77.000 90.0 1 50 30 80 80
PICK 404 1 1 1 0 235.000 77.000 90.0 1 50 30 80 80 0.2 0.1
COMMENT : In case a deviating dump position is needed enter
COMMENT : DUMP position_x position_y
DUMP 120.000 117.000
COMMENT mount coordinates are in board coordinates
COMMENT comp_ref /ci/ix/bd/fd /pk /mnt_x /mnt_y /mnt_phi /align_phi
MOUNT U2313 1 1 3 303 1 -198.780 85.390 0.0 0.0
MOUNT U4404 1 1 3 301 1 -210.080 116.740 0.0 0.0
MOUNT U2905 1 2 3 401 1 -253.130 71.040 90.0 90.0
MOUNT U2909 1 2 3 303 1 -265.830 75.870 90.0 90.0
...
...
...
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 4-33
Mount Program
syntax: feeder_pos_nr + pick_pos_nr + feeder_id + feeder_type + component_id +
package_id / smd_info_file_id [+ feeder_phi [+ feeder_pick_vector] ]
component_id (component_id)
type: string
length: 1..20
description: Denotes the electrical identfication of the component (e.g. part number,
ordering code, stock code).
smd_info_file_id (smd info)
type: string
format: <file name>[.”<file name extension>]
length/range: <file name> : 1..8
<file name extension> : LAS | FCA | CA
description: Denotes the SMD info file to be used.
NOTE: Extension LAS is only used in AS LAS . FCA and CA only used in AS WVM .
NOTE: FCA refers to SMD Info Files of symmetrical components.
CA refers to SMD Info Files of asymmetrical components.
NOTE: If no file name extensions are used, the system refers by default to SMD Info Files with extensions
LAS or FCA . In the case of AS WVM it is therefore obligatory to use an smd_info_file_id with
the extension CA if you are using components which are defined as assymetrical.
feeder_phi (feeder_phi)
type: real
range: -180.0 .. 180.0 (degrees)
description: Orientation of the component in the feeders pocket coordinate system,
relative to the components coordinate system.
feeder_pick_vector (only used for WVM)
feeder_pick_X (f_pick_x)
type: real
range: -1.0 ... 1.0 (mm) for nozzle PA 2748/10
-1.5 ... 1.5 (mm) for nozzles PA 2748/20 & PA 2748/30
description: The additional X-offset with which the nozzle picks up the component,
relative to the centre of the feeders pick pocket.
feeder_pick_Y (f_pick_y)
type: real
range: 0 .. 2.0 (mm)
description: The additional Y-offset with which the nozzle picks the component,
relative to the centre of the feeders pick pocket.
Mount Program
User Reference Manual 4022 591 96082
4-34 FCM Multiflex 02.02
Placement Module Activities (continued)
AS LAS/WVM 3
COMMENT
COMMENT Placement module actions for position 3
COMMENT
COMMENT PPU_id /nozzle_id /clow/chgh/cidx
MUP VISION 4900 20 50 1
BOARD_ROTATION 0
COMMENT index coordinates are relative to placement module origin
COMMENT indx /brd /refholex /refholey /board_x /board_y
INDEX 1 3 -7.000 143.500 269.000 138.000
INDEX 2 3 3.000 143.500 339.000 138.000
INDEX 3 2 -157.000 143.500 119.000 138.000
INDEX 4 2 -77.000 143.500 199.000 138.000
COMMENT feed/pick /feeder_id /type /component_id /smd info [/feeder_phi /f_pick_x /f_pick_y]
FEEDER 301 1 T12-P T 93697451 SO-8 0.0
FEEDER 303 1 T12-P T 93697711 SO-8 0.0
FEEDER 307 1 T12-P T 93697706 SO-8 0.0
FEEDER 401 1 T16-P T 286114465Z SO-16 0.0
FEEDER 404 1 T24-P T 286114414A VSOP.CA 0.0 0.2 0.1
COMMENT pick coordinates are relative to placement module origin
COMMENT fd /pk/psh/mrp/mra/pick_x /pick_y/pick_phi/na/prf/arf/ale/ple [/c_pick_x/c_pick_y]
PICK 301 1 1 1 0 19.000 77.000 90.0 1 50 28 80 80
PICK 303 1 1 1 0 51.000 77.000 90.0 1 50 28 80 80
PICK 307 1 1 1 0 99.000 77.000 90.0 1 50 28 80 80
PICK 401 1 1 1 0 187.000 77.000 90.0 1 50 30 80 80
PICK 404 1 1 1 0 235.000 77.000 90.0 1 50 30 80 80 0.2 0.1
COMMENT : In case a deviating dump position is needed enter
COMMENT : DUMP position_x position_y
DUMP 120.000 117.000
COMMENT mount coordinates are in board coordinates
COMMENT comp_ref /ci/ix/bd/fd /pk /mnt_x /mnt_y /mnt_phi /align_phi
MOUNT U2313 1 1 3 303 1 -198.780 85.390 0.0 0.0
MOUNT U4404 1 1 3 301 1 -210.080 116.740 0.0 0.0
MOUNT U2905 1 2 3 401 1 -253.130 71.040 90.0 90.0
MOUNT U2909 1 2 3 303 1 -265.830 75.870 90.0 90.0
...
...
...