FCM_User Reference Manual.pdf.pdf - 第128页

MIS User Re ference Manual 4022 5 91 96082 5-36 F CM Mult ifl ex 02.02 G rap h ex pla nat ion, S peci fi c LAS m odul e, Mi sal ig n errors option fcm0 534a / 0535 a.ti f SCREE N 5-2 9 [Proc ess g r aph. ..] Specific LAS…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-35
MIS
TABLE 5-15
Graph legend Explanation
Manual pick err.
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
misalign
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD could not properly be aligned
lost BA
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
lost AA
FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
total number of manual pick retries per feeder
retained
FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying to
place it on the board
total number per feeder of manual pick retries
skipped total number per feeder of picked SMDs that are
not placed (dumped) as a result of selecting [Skip
action] or [Skip board] in the [Error Recovery]
dialogue
MIS
User Reference Manual 4022 591 96082
5-36 FCM Multiflex 02.02
Graph explanation, Specific LAS module, Misalign errors option
fcm0534a/0535a.tif
SCREEN 5-29 [Process graph...] Specific LAS module, Misalign errors screen examples
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used feeders
Placed scale for total number of placed SMDs
total number of placed SMDs per feeder (blue
circle)
Size Length total number of automatic and manual pick
retries per feeder with the cause:
the measured SMD length exceeded the length
as specified in the SMD info file
With total number of automatic and manual pick
retries per feeder with the cause:
the measured SMD length exceeded the width
as specified in the SMD info file
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-37
MIS
TABLE 5-16
Graph legend Explanation
Offset X total number of automatic and manual pick retries
per feeder with the cause:
the measured X-offset exceeded the X reject level
as specified in the SMD info file
Y total number of automatic and manual pick retries
per feeder with the cause:
the measured Y-offset exceeded the Y reject level
as specified in the SMD info file
Phi total number of automatic and manual pick retries
per feeder with the cause:
the measured Phi-offset exceeded the Phi reject
level as specified in the SMD info file
Unmeas. total number of automatic and manual pick retries
per feeder with the cause:
unmeasureable, due to laser errors that occurred
during the align measurement (e.g. laser dirty
error)