FCM_User Reference Manual.pdf.pdf - 第126页
MIS User Re ference Manual 4022 5 91 96082 5-34 F CM Mult ifl ex 02.02 Grap h explanation, S pecific module, A ll errors opt ion fcm0 532a / 0533 a.ti f SCREE N 5-2 8 [Proc ess g r aph. ..] Specific module, All errors sc…

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-33
MIS
TABLE 5-14
Graph legend Explanation
Manual pick err.
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
misalign
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD could not properly be aligned
lost BA
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
lost AA
■ FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
■ total number of manual pick retries per feeder
retained
■ FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying to
place it on the board
■ total number per feeder of manual pick retries
skipped total number per feeder of picked SMDs that are
not placed (dumped) as a result of selecting [Skip
action] or [Skip board] in the [Error
Recovery] dialogue

MIS
User Reference Manual 4022 591 96082
5-34 FCM Multiflex 02.02
Graph explanation, Specific module, All errors option
fcm0532a/0533a.tif
SCREEN 5-28 [Process graph...] Specific module, All errors screen examples
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used feeders
Placed scale for total number of placed SMDs
total number of placed SMDs per feeder (blue
circle)
Auto retries aft. pick total number of automatic pick retries per feeder
that occurred after SMD was missing
immediately after pick action
misalign total number of automatic pick retries per feeder
that occurred after SMD could not properly be
aligned
align total number of automatic pick retries per feeder
that occurred after SMD was missing upon
starting the align action (WVM only)

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-35
MIS
TABLE 5-15
Graph legend Explanation
Manual pick err.
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
misalign
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD could not properly be aligned
lost BA
■ FCM Multiflex stopped after having reached
the auto retry limit
■ total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
lost AA
■ FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
■ total number of manual pick retries per feeder
retained
■ FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying to
place it on the board
■ total number per feeder of manual pick retries
skipped total number per feeder of picked SMDs that are
not placed (dumped) as a result of selecting [Skip
action] or [Skip board] in the [Error Recovery]