FCM_User Reference Manual.pdf.pdf - 第115页
4022 591 96082 User Re ference Manual 02.02 FCM Multiflex 5-23 MIS TA B L E 5 - 9 Report text Explanation Misalign det ails (= Au to matic + manual retries) (continued) Lead pitch the visi on system detected that the di …

MIS
User Reference Manual 4022 591 96082
5-22 FCM Multiflex 02.02
TABLE 5-8
Manual pick error ■ FCM Multiflex stopped after having reached the auto
retry limit
■ total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
missing before
align
■ FCM Multiflex stopped after having reached the auto
retry limit
■ total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
misalign
■ FCM Multiflex stopped after having reached the auto
retry limit
■ total number of manual pick retries per feeder
after SMD could not properly be aligned
missing after
align
■ FCM Multiflex stopped immediately after the SMD was
lost after performing the alignment action
■ total number of manual pick retries per feeder
retained after
place
■ FCM Multiflex stopped immediately after the SMD was
still present on the nozzle after trying to place
it on the board
■ total number of manual pick retries per feeder
not placed
(skipped)
total number of picked SMDs per feeder that are not placed
(dumped) as a result of selecting [Skip action] or [Skip board]
in the [Error
Recovery] dialogue
Misalign
details
(= Automatic +
manual retries)
X-offset the measured X-offset exceeded the X-reject level as specified
in the SMD info file
Y-offset the measured Y-offset exceeded the Y-reject level as specified
in the SMD info file
Phi-offset the measured Phi-offset exceeded the Phi reject level as speci-
fied in the SMD info file
Width the measured SMD width exceeded the width (tolerance) as
specified in the SMD info file
Length the measured SMD length exceeded the length (tolerance) as
specified in the SMD info file
Not measurable the laser align or vision system was not able to measure the
SMD that was picked up (LAS: a laser error occurred during the
align process; WVM: not all sides of the SMD within the cam-
era’s field of view)
Lead count the vision system detected that the number of leads measured
on the North/South and/or East/ West side of the SMD are not
the same (WVM only)

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-23
MIS
TABLE 5-9
Report text Explanation
Misalign details
(= Automatic +
manual retries)
(continued)
Lead pitch the vision system detected that the distance
between all individual leads on one (or more)
side(s) of the component is not within the
required tolerance (WVM only)
Lead width the vision system detected that the SMD’s
lead width is out of tolerance (WVM only; for
asymmetric SMDs with only one lead at one
side, as “lead pitch” does not exist in this
case)
Coplanarity the vision system detected that not all individ-
ual leads on one (or more) side(s) of the SMD
are positioned in-line (for instance, one or
more leads are bent) (WVM only)
Component geometry the vision system detected that the leads on
the North/South and/or East/West side of the
SMD are not exactly opposite each other (for
SMDs with leads on all four sides only) (WVM
only)
Retry limit the number of automatic retries after which
the FCM Multiflex will stop with a pick error or
misalign error; this number is defined in the
action spec (see SCREEN 5-14)

MIS
User Reference Manual 4022 591 96082
5-24 FCM Multiflex 02.02
Report text explanation, BVM option
TABLE 5-10
fcm0525a.tif
SCREEN 5-18 [Process report...], BVM screen example
Report text Explanation
BVM - Errors Errors total number of times the BVM was unable to
measure a board
Retries total number of manual initiated BVM retries
Time lost due to
BVM errors
(hh:mm:ss)
Response total waiting-for-operator time during a BVM
error (time between occurrence of the error
and the moment the operator starts with
recovery) expressed in hh:mm:ss, where
hh = hours, mm = minutes, and ss = seconds
note that “10 seconds” is denoted as only “10”
instead of “00:00:10”
Down the total time the FCM Multiflex has stopped
due to a BVM error; expression details, see
above
BVM - Disabled
circuits
Count the total number of circuits that has been disa-
bled because of a badmark detection