Mount Program User Re ference Manual 4022 5 91 96082 4-12 F CM Mult ifl ex 02.02 4 .2.3 Transpo r t Ac tivities AS T C COMM ENT COMM ENT Tr ansport actions COMM ENT SETUP SENSO R P OSITI ON A T Run- out I S 2 019.00 0 MM…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 4-11
Mount Program
4.2.2.8 NUMBER_OF_BOARDS
syntax: number_of_boards
type: integer
range: 1.. 24
description: Denotes the maximum amount of boards that can be held
on the transport beam.
4.2.2.9 CYCLE_TIME
syntax: expected_cycle_time
type: real
range: > 0.0 (seconds)
description: Denotes the cycle time of the line for which the action
specification is valid.
Mount Program
User Reference Manual 4022 591 96082
4-12 FCM Multiflex 02.02
4.2.3 Transport Activities
AS TC
COMMENT
COMMENT Transport actions
COMMENT
SETUP SENSOR POSITION AT Run-out IS 2019.000 MM
LIFTUP -440.000
COMMENT step /value
STEP 1 70.000
STEP 2 70.000
STEP 3 80.000
STEP 4 80.000
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 4-13
Mount Program
4.2.3.1 LIFTUP
syntax: tc_lift_up_position
type: real
range: -440.000 .. 40.000 (mm)
description: Specifies the X-position of the left-most dowel pin on the
transport beam, at the beam lift-up position. It is
referenced from the machine origin.
4.2.3.2 STEP
syntax: index_nr + index_step
index_nr (step)
type: integer
range: 1..9
description: The number of the transport index to which the record
applies.
index_step (value)
type: real
range: 0.000 .. 480.000 mm
description: Gives the distance over which the transport beam should
be moved when starting an index. Deviation from the
standard index schemes is allowed, but not encouraged.