FCM_User Reference Manual.pdf.pdf - 第236页

Pr oduc t Ch ang e Ov er User Re f eren ce Manu al 4022 591 960 82 6-44 FCM M ult ifle x 02.02 SCREEN 6- 38 ■ Sel ect the cir cuit concern ed in the [Circ uit] box ■ Sel ect [Measure Badmar k] The s y stem will try t o m…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-43
Product Change Over
The test results of the measurement will be shown in the [Status Badmark Meas-
urement]
box.
NOTE: Automatic teaching of a standard badmark is only possible if both grey
levels (badmark and background) are visible in the [Area of Interest] (see
also the section Area of Interest). This implies that the camera must be
positioned slightly off-centre when the size of the badmark exceeds the
cameras field of view.
NOTE: The automatic teach function of the badmark does not always supply
optimal results, especially for the grey level and threshold settings. If this
is the case, please refer to the section Light Level and Threshold for manual
teaching.
Select [Store] to store the taught data in the current data base
1
Select [Next Badmark] to go to the next badmark to be measured
Select
[Type...] to change the type of badmark to be taught
6.5.1.2 Measure Badmark
TABLE 6-14
Select [Measure Badmark...]
The badmark to be measured must be selected from the action spec, which lists all
used circuits and badmarks
1. Whenever a badmark with the identification
number of the taught badmark is selected in an
action spec, these stored settings will be used.
)XQFWLRQ $XWKRUL]DWLRQ
Check the results of a badmark measurement with the current
teach data.
- Operator
- Supervisor
- Maintenance/ Service Engineer
Product Change Over
User Reference Manual 4022 591 96082
6-44 FCM Multiflex 02.02
SCREEN 6-38
Select the circuit concerned in the
[Circuit] box
Select
[Measure Badmark]
The system will try to measure the selected (fiducial-type) badmark; the result will
be displayed in the
[Status Badmark Measurement] box.
6.5.1.3 Save Badmark Teach Data...
TABLE 6-15
This is relevant when teach data of a certain badmark type has to be modified, but
the current data is expected to have future use.
NOTE: For back-up purposes it is better to archive on floppy disk.
)XQFWLRQ $XWKRUL]DWLRQ
Save teach data - that was stored in the teach mode in the current
(active) database - to a selected file on disk.
- Supervisor
- Maintenance/ Service Engineer
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-45
Product Change Over
6.5.1.4 Load Badmark Teach Data...
TABLE 6-16
!
WARNING: THE OLD TEACH DATA OF ALL BADMARK TYPES IN THE CURRENT (ACTIVE)
DATABASE WILL BE OVERWRITTEN!
6.5.1.5 Copy From Archive...
TABLE 6-17
The archive disk can be a floppy disk drive or any other in- or external disk drive.
From there it can be moved to the current (active) database by the
[Load Badmark
Teach Data...]
command.
6.5.1.6 Copy To Archive...
TABLE 6-18
The archive disk can be a floppy disk drive or any other in- or external disk drive.
6.5.1.7 Delete...
TABLE 6-19
)XQFWLRQ $XWKRUL]DWLRQ
Copy teach data from a selected file on disk to the current (active)
database.
- Supervisor
- Maintenance/ Service Engineer
)XQFWLRQ $XWKRUL]DWLRQ
Copy teach data from the archive disk drive to a file on the (system)
disk.
- Supervisor
- Maintenance/ Service Engineer
)XQFWLRQ $XWKRUL]DWLRQ
Copy teach data from a file on the (system) disk to the archive disk
drive.
- Supervisor
- Maintenance/ Service Engineer
)XQFWLRQ $XWKRUL]DWLRQ
Delete badmark teach data files. - Supervisor