a3369b.pdf - 第105页

Communication Interfaces 96 VTK - TR -BA- 171e - 1 - User Man u al MDS 3080 -V 33 SYSTEM:DOSOKDELAY:OFF Descript ion: This command deactivates t he DOSOK - Delay. When t his is true, the lengt h of a delay i s not added …

100%1 / 195
Communication Interfaces
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
95
28 SYSTEM:FIRSTDROP:OFF
Description:
This command deactivates the first drop function.
Example:
Input:
SYSTEM:FIRSTDROP:OFF
Result:
The first drop mode is deactivated.
Return:
OK
29 SYSTEM:FIRSTDROP:ON
Description:
This command activates the first drop function.
Example:
Input:
SYSTEM:FIRSTDROP:ON
Result:
The first drop mode is activated.
Return:
OK
30 SYSTEM:FIRSTDROP:ADJUST:<starting value>
Description:
This command starts the first drop adjust.
The starting value is between 2 and 50. Further control of the first drop
adjust is done via the commands “KEY:ENTER”, “KEY:ESCAPE” and
“KEY:ADJUST”.
Details you will find in paragraph 8.2.4, page 126.
Example:
Input:
SYSTEM:FIRSTDROP:ADJUST:10
Result:
The first drop adjust is started.
Return:
Fill up with Medium!!!!!
31 SYSTEM:FIXEDADJUST:OFF
Description:
This command deactivates the fixed adjust function.
Example:
Input:
SYSTEM:FIXEDADJUST:OFF
Result:
The fixed adjust mode is deactivated.
Return:
OK
32 SYSTEM:FIXEDADJUST:ON
Description:
This command activates the fixed adjust function.
Example:
Input:
SYSTEM:FIXEDADJUST:ON
Result:
The fixed adjust mode is activated.
Return:
OK
Communication Interfaces
96
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
33 SYSTEM:DOSOKDELAY:OFF
Description:
This command deactivates the DOSOK-Delay.
When this is true, the length of a delay is not added to the length of the
DOSOK signal. (Default setting is “delay OFF”.)
Example:
Input:
SYSTEM:DOSOKDELAY:OFF
Result:
Deactivates the DOSOK-delay.
Return:
OK
34 SYSTEM:DOSOKAYDELAY:ON
Description:
This command activates the DOSOK-Delay.
When this is true, the length of a delay is added to the length of the DOSOK
signal. (Default setting is “delay OFF”.)
Example:
Input:
SYSTEM:DOSOKDELAY:ON
Result:
Activates the DOSOK-delay.
Return:
OK
35 SYSTEM:SINGLEDOSOK:SETUP
Description:
This command sets the Single-DOSOK signal to “Setup”. The length of the
Single-DOSOK signal is that of the setup. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:SETUP
Result:
The Single-DOSOK is set to “setup”.
Return:
OK
36 SYSTEM:SINGLEDOSOK:PULSE
Description:
This command sets the Single-DOSOK signal to “Pulse”. The length of the
Single-DOSOK signal is that of a pulse. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:PULSE
Result:
The Single-DOSOK is set to “pulse”.
Return:
OK
Communication Interfaces
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
97
37 SYSTEM:PASSWORD:<Your password>
Description:
This command sends the 6-digit password to unlock the keypad after a
PLC-trigger. Each digit can be either of 1, 2, 3 or 4 (representing the keys
[], [], []and []resp.)
Example:
Input:
SYSTEM:PASSWORD:111111
Result:
The keypad is unlocked.
Return:
OK
38 SYSTEM:PASSWORD:OFF
Description:
This command deactivates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:OFF
Result:
The password is deactivated.
Return:
OK
39 SYSTEM:PASSWORD:ON
Description:
This command activates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:ON
Result:
The password is activated.
Return:
OK
40 SYSTEM:PASSWORD:SET:<Your password>
Description:
This command sets the 6-digit password, which can unlock the keypad
after a PLC-trigger. The password is 6-digit, with each digit either of 1, 2, 3
or 4 (representing the keys “[], [], []and []resp.).
The password has to be exactly six digits long; anything else would lead to
an error.
Example:
Input:
SYSTEM:PASSWORD:SET:111111
Result:
The 6-digit password is set.
Return:
OK