6.6 Initial Liquid Supply
– Step 1: If not using a prefilled cartridge, fill an empty one with the required fluid, till up to
80 % of its capacity.
– Step 2: Insert the cartridge into the corresponding holder and screw it onto the Luer-Lock
connector, rotating clockwise.
– Step 3: Place the compressed-air adaptor onto the cartridge and rotate clockwise until it
latches in place.
– Step 4: Connect the PVC hose with coupler plug KS4-CK-6 to air supply. A coupler socket type
KD4-1/2-A is required.
– Step 5: After establishing a convenient dispensing pressure, activate the pneumatic supply.
IMPORTANT NOTE
Check for leakage
All of the parts must be installed correctly, and the entire configuration must be leak-tight –
otherwise the dispensing fluid can trickle out in an uncontrolled manner.
Valves designed by VERMES Microdispensing can be operated at a relatively low supply pressure,
in the range between 0 bar and 4 bar. This upper limit should not be exceeded in normal
applications.
Standard values:
• Low-viscous fluids (e.g. water): 0.5 – 1.5 bar
• Medium viscosity (e.g. SMT-adhesives): 1.5 – 2.0 bar
IMPORTANT NOTE
Do not activate system without dispensing medium
Except for the adjust, do not activate the system “dry” (i.e. without dispensing medium).
Otherwise, it might damage the system. For flushing the valve keep within the following limits:
• Needle Lift max. 80
• Falling min. 0.4
6.7 Removing Air Inclusions from the Fluid Box
Air must be removed from the fluid box, for instance after the exchange of a cartridge.
Save the current dispensing parameters beforehand (see paragraph 7.6, page 63).
Confirm the following parameter selection:
Rising 0.5, Open Time 1.5, Falling 0.4, Delay 5–30, Needle Lift 75, Number of Pulses 500–2000
Dispense a quantity of ca. 500 to 2000 shots by pressing [trig].
When this measure is complete, retrieve the initial parameters stored beforehand (see
paragraph 7.7, page 63) and start the dispensing process.

Initial Operation
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
57
6.8 Parameter Input and Start
– Step 1: Enter the dispensing parameters (either recommended by the manufacturer or
determined in your own experiments) into the submenu “Pulse Parameters” of the control
unit (see paragraph 4.5.2, page 29).
– Step 2: Press [enter] to acknowledge the selection.
– Step 3: Return to the first level of the menu by pressing [esc] repeatedly.
– Step 4: Start the dispensing process by pressing [trig].
INFORMATION
Starting the dispensing process
A dispensing process can only be initiated in the first menu level by all the usual methods.
Starting it in the other menu levels is only possible with the key [trig].

Operation
58
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
7 Operation
7.1 Triggering a Dispense Sequence
There are three different options to trigger a dispense sequence:
• via keypad on the control unit MDC
Press the [trig] button, a dispensing sequence with pre-set parameters will be triggered.
• via RS-232C command
Use the command “VALVE:OPEN” (further commands in paragraph 8.1.2, page 84).
• via PLC-signal
Real time triggering by direct I/O (recommended length of signal: between 0.0001 ms and
35 ms; not relevant for Infinite Mode and External Mode)
7.2 Dispensing and Positioning of Dots (Modes)
To combine a multitude of dots to a predefined structure (e.g. a line or a circle), use one of the
following modes:
• Burst Mode
A single trigger impulse by PLC signal causes a predefined number of dispense cycles.
Number of Pulses: predefined value (e.g. 1–32000)
• Single-Shot Mode
Each dispense point is triggered by an individual PLC signal. When dispensing a continuous
feature (such as a straight line or a circle), the frequency of the dispense trigger signal should
be proportional to the trajectory speed of the axis system. This is necessary to achieve a
continuous line width.
Number of Pulses: “1”
• Infinite Mode
– Continuous dispensing as long as the PLC trigger input is “logic 1”. Dispensing will stop when
the signal is changed to “logic 0”
– Number of Pulses:
– “infinite” (when programmed through keypad)
– “0” (when programmed through RS-232C)
The parameters Rising, Falling, Delay, Needle Lift and Open Time use the values preset in the
menu. Is the PLC trigger signal “logic 1”, the MDC sends dispensing impulses, until the signal
changes to “logic 0”.
IMPORTANT NOTE
No dispending at high frequencies for too long
If the valve is used at high frequencies (hundreds of Hertz) for too long, there is a danger of
overheating. For this reason, the system is switched OFF automatically after some time. Do not
dispense for longer than 12 s without a break, when using these high frequencies.
• Scenario Mode
A complex set of shots is defined via a scenario. This allows the dispensing even of very
complex structures, since up to ten different segments, each with their own set of
parameters, can be combined. Four different scenarios can be saved.
The above mentioned methods for triggering are available.