a3369b.pdf - 第106页
Communication Interfaces VTK - TR -BA- 171e - 1 - User Manua l MDS 3080 -V 97 37 SYSTEM:PASSWORD:<Your password> Descript ion: This command sends the 6 - digit p assword to unlock t he keyp ad after a PLC - trigger…

Communication Interfaces
96
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
33 SYSTEM:DOSOKDELAY:OFF
Description:
This command deactivates the DOSOK-Delay.
When this is true, the length of a delay is not added to the length of the
DOSOK signal. (Default setting is “delay OFF”.)
Example:
Input:
SYSTEM:DOSOKDELAY:OFF
Result:
Deactivates the DOSOK-delay.
Return:
OK
34 SYSTEM:DOSOKAYDELAY:ON
Description:
This command activates the DOSOK-Delay.
When this is true, the length of a delay is added to the length of the DOSOK
signal. (Default setting is “delay OFF”.)
Example:
Input:
SYSTEM:DOSOKDELAY:ON
Result:
Activates the DOSOK-delay.
Return:
OK
35 SYSTEM:SINGLEDOSOK:SETUP
Description:
This command sets the Single-DOSOK signal to “Setup”. The length of the
Single-DOSOK signal is that of the setup. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:SETUP
Result:
The Single-DOSOK is set to “setup”.
Return:
OK
36 SYSTEM:SINGLEDOSOK:PULSE
Description:
This command sets the Single-DOSOK signal to “Pulse”. The length of the
Single-DOSOK signal is that of a pulse. (Default setting is “Pulse”.)
Example:
Input:
SYSTEM:SINGLEDOSOK:PULSE
Result:
The Single-DOSOK is set to “pulse”.
Return:
OK

Communication Interfaces
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
97
37 SYSTEM:PASSWORD:<Your password>
Description:
This command sends the 6-digit password to unlock the keypad after a
PLC-trigger. Each digit can be either of 1, 2, 3 or 4 (representing the keys
“[←]”, “[↑]”, “[↓]” and “[→]” resp.)
Example:
Input:
SYSTEM:PASSWORD:111111
Result:
The keypad is unlocked.
Return:
OK
38 SYSTEM:PASSWORD:OFF
Description:
This command deactivates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:OFF
Result:
The password is deactivated.
Return:
OK
39 SYSTEM:PASSWORD:ON
Description:
This command activates the password, which unlocks the keypad after a
PLC-trigger.
Example:
Input:
SYSTEM:PASSWORD:ON
Result:
The password is activated.
Return:
OK
40 SYSTEM:PASSWORD:SET:<Your password>
Description:
This command sets the 6-digit password, which can unlock the keypad
after a PLC-trigger. The password is 6-digit, with each digit either of 1, 2, 3
or 4 (representing the keys “[←]”, “[↑]”, “[↓]” and “[→]” resp.).
The password has to be exactly six digits long; anything else would lead to
an error.
Example:
Input:
SYSTEM:PASSWORD:SET:111111
Result:
The 6-digit password is set.
Return:
OK

Communication Interfaces
98
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
41 SYSTEM:AUXILIARYMODE:ON
Description:
This command activates the auxiliary mode.
In auxiliary mode, the valve is disconnected. All other functionalities of the
MDC can be used and tested.
To turn the auxiliary mode OFF, use service code 1000 (see paragraph 4.5.6
,
page 33) or re-start the MDC with the command MDC:RESTART.
Example:
Input:
SYSTEM:AUXILIARYMODE:ON
Result:
The auxiliary mode is activated.
Return:
OK
42 TEMP:? TEMP = temperature
Description:
Ignore this command since it is inapplicable to this system.
43 TEMP:<Set point in °C> (TEMP = temperature)
Description:
Ignore this command since it is inapplicable to this system.