Communication Interfaces VTK - TR -BA- 171e - 1 - User Manua l MDS 3080 -V 87 RS - 232C c o mman ds Reac tion ti me ( ms) For baud rate: 9600 bits/s 115200 bits/ s 71 . WR ITE:L CD:<te xt> 60 40 72 . S CENARIO:S TA…

Communication Interfaces
86
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
RS-232C commands Reaction time (ms)
For baud rate:
9600 bits/s 115200 bits/s
35. SYSTEM:SINGLEDOSOK:SETUP
80
70
36. SYSTEM:SINGLEDOSOK:PULSE
80
60
37. SYSTEM:PASSWORD:<your password>
60
40
38. SYSTEM:PASSWORD:OFF
80
60
39. SYSTEM:PASSWORD:ON
80
60
40. SYSTEM:PASSWORD:SET:<your password>
80
70
41. SYSTEM:AUXILIARYMODE:ON
130
110
42. TEMP:?
inapplicable to the system
43. TEMP:<set point in °C>
inapplicable to the system
44. TRIGGER:SET:?
90
70
45. TRIGGER:SET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
60
60
46. TRIGGER:SET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>,1
90
80
47. TRIGGER:ASET:?
380
340
48. TRIGGER:ASET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
70
50
49. TRIGGER:ASET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>,1
100
80
50. STRIGGER:SET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
100
90
51. STRIGGER:SET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>,1
130
110
52. STRIGGER:ASET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
400
350
53. STRIGGER:ASET:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>,1
430
380
54. VALVE:UP
60
40
55. VALVE:DOWN
60
40
56. VALVE:CHECK:OFF
120
110
57. VALVE:CHECK:ON
120
110
58. VALVE:CHECK:<value>
50
40
59. VALVE:OPEN
60
40
60. VALVE:OPEN:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
70
50
61. VALVE:OPENS<setup no.>
60
40
62. VALVE:AOPEN
60
40
63. VALVE:AOPEN:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
60
50
64. VALVE:AOPENS<setup no.>
60
40
65. SVALVE:OPEN
90
90
66. SVALVE:OPEN:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
90
80
67. SVALVE:OPENS<setup no.>
90
340
68. SVALVE:AOPEN
390
340
69. SVALVE:AOPEN:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
400
350
70. SVALVE:AOPENS<setup no.>
80
340

Communication Interfaces
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
87
RS-232C commands Reaction time (ms)
For baud rate:
9600 bits/s 115200 bits/s
71. WRITE:LCD:<text>
60
40
72. SCENARIO:STATUS
680
340
73. SCENARIO:OFF
90
70
74. SCENARIO:ON
80
70
75. SCENARIO:PLCSTOP:1:OFF
100
90
76. SCENARIO:PLCSTOP:1:ON
100
80
77. SCENARIO:SAVE:<scenario no.>:<values>
100
90
78. SCENARIO:READ:<scenario no.>
680
340
79. SETUP:SAVE:<setup no.>:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
90
80
80. SETUP:ASAVE:<setup no.>:<RI>,<OT>,<FA>,<NL>,<NP>,<DL>
90
70
81. SETUP:READ:<setup no.>
100
70
82. SETUP:AREAD:<setup no.>
400
340
83. BAUDRATE:0/1/2/3/4
60
40
84. GETTD
90
70
85. MDC:RESTART
210
190

Communication Interfaces
88
VTK-TR-BA-171e-1 - User Manual MDS 3080-V
8.1.2.2 Explanations
0
1 *ESR? ESR? = Event Status Register Query
Description:
This command shows the latest error codes created by the system, starting
with the latest event. At the most 50 error messages will be shown.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”.
Example:
Input:
*ESR?
Result:
List of the (up to 50) latest error messages
Return:
8 199 VALVE ERROR 08FU04 09:16:38 2018-01-21
9 104 INCORR. VALVE 08FU04 09:16:21 2018-01-21
2 *ESR2? ESR2? = Event Status Register Query 2
Description:
This command shows the latest error codes created by the system, starting
with the latest event. There will be shown a max of 50 error messages.
Each error messages also includes the valve ID (if known) and a time and
date stamp. If the RTC of the MDC is defect, the value will be given as
“00:00:00 2014-01-01”. Additionally the parameters of setups 0 to 3 before
the error are listed.
Example:
Input:
*ESR2?
Result:
List of the (up to 50) latest error messages with parameters
Return:
20 199 VALVE ERROR 000000 09:16:38 2018-01-21
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0
27 104 INCORR. VALVE 08FU04 09:16:21 2018-01-21
30, 5, 30, 80, 1, 20
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
50, 20, 20, 80, 1, 100
3 *IDN? IDN? = Identification Query
Description:
Device specific information, formatted as follows: type (hv, or lv), software
version. Important for contact with our Technical Support.
Example:
Input:
*IDN?
Result:
Micro Dispenser LV, 4071LU1-D
Return:
Micro Dispenser LV, 4071LU1-D
4 *OPC? OPC? = Operation Complete Query
Description:
Monitoring the last trigger impulses. After this, the counter is cleared to
zero.
Example:
Input:
*OPC?
Result:
Number of the last pulses. Clears the counter to zero.
Return:
6699