00198783-01_AI_Kit_TwinVHF_Gantry_SXV3_de_en.pdf - 第103页

2 Brief Description 2.2 Prerequisites Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal Reconfiguration Kit Twin VHF with Gantry 06/2020 103 2.2.1 SIPLACE SX "Prepar…

100%1 / 152
2 Brief Description
2.2 Prerequisites
102 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
SIPLACE SX2
Fig.17: Stationary cameras on the SIPLACE SX2
1. Location 1 in outer position
2. Location 2 in outer position
3. Gantry 1
4. Gantry 2
5. IC camera and/or FC camera/3D coplanarity module (location1)
You can only install either an FC camera or a 3D coplanarity module!
6. IC camera (location2)
2.2 Prerequisites
This option is possible for SIPLACE SX1, SX1prepared and SX2 machines.
Serial number from Rxxxx
Station software 713.0
SIPLACE Pro 17.0
WPC5/6 - 45 mm (serial numbers from B3xxx/C3xxx)
This WPC is needed for feeding in components with heights up to 40 mm.
A combination with the "Smart Pin Support" option is also possible. In this case, you need the
appropriately adapted pin picker.
2 Brief Description
2.2 Prerequisites
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
103
2.2.1 SIPLACE SX "Prepared"
Fig.18: The SIPLACE SX must be in the delivery state "Prepared".
This can be recognized by the presence of a trailing cable (1) and the control unit for the main axes
(MGCU (2)
). This applies for the SIPLACE SX+ machine, in order to retrofit gantry 1 at location 1 or
for the SIPLACE SX1 "Prepared", in order to retrofit gantry 2 at location 2.
The trailing cable is packed in a black plastic case and is fixed at the side (1).
If this is not the case, your machine will need to be retrofitted accordingly. Contact your SIPLACE
Service team for details.
2 Brief Description
2.3 Scope of Delivery
104 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
2.3 Scope of Delivery
Required parts:
Option: gantry with VHF TH SIPLACE SX V3 [00520557‑xx] (alternative: [03220743‑xx])
Contents:
Quant-
ity
Designation Item no.
1 GR gantry 40 mm SX V3 03220745-xx
2 VHF-Twin module 03096701-xx
2 MHCU assembly, compatible 03090990-xx
1 Camera lens hood assembly VHF TwinHead 03104859-xx
1 PCB / B-Base adapter TWIN 03055517-xx
1 Nozzle set, TwinHead 03019633-xx
1 Cable set TwinHead / B series 03065968-xx
1 Hose system TwinHead, VHF SX1/2 03106594-xx
1 Blanking plug QSC-6H 00337891-xx
1 Blanking plug QSC-4H 00330249-xx
2 Standard nozzle 508 VHFM assy. 03094257-xx
1 ISO 4762 - M 3 x 6-A2-70 03042541-xx
8 ISO 4762 - M 4 x 14-8.8, zinc, DSP 03069100-xx
2 Cable ties B=2.5mm, L=102mm Panduit 00308458-xx
Fig.19: PCB camera type 34HU
PCB camera type 34HU GigE
[03218360‑xx] (part of the gantry
[03220745‑xx], see above)
 NOTICE!
This PCB camera differs from the
standard camera. Remember this e.g.
when ordering spare parts.
.
Gantry carrier [00519814-03]
The gantry is supplied on a gantry carrier.
This gantry carrier must have at least function state 03 for use with the 40mm gantry.