00198783-01_AI_Kit_TwinVHF_Gantry_SXV3_de_en.pdf - 第118页

3 Fitting the gantry 3.4 Converting the Cover 118 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal Reconfiguration Kit Twin VHF with Gantry 06/2020 3.4 Converting the Co…

100%1 / 152
3 Fitting the gantry
3.3 Assembling the SIPLACE Twin VHF
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
117
Fig.37: SX12 hoses for Twin VHF
1 Pneumatic distributor 2 Connection for pressure control valve
3 Hose to Pin Picker (Smart Pin Support
option)
4 Connection for return unit
5 Connection for exhaust tube 6 Silencer discharged air
7 Head boards
► Connect the discharged air connections for the two modules to the silencer.
► Connect the two return units, vacuum generator and pressure control valves with the pneu-
matic distributor.
► Connect the head boards with the base adapter, using two flat ribbon cables in each case.
3 Fitting the gantry
3.4 Converting the Cover
118 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
3.4 Converting the Cover
When using the SIPLACE WPC5/6 for high components, you need to convert the cover. The new
cover has a recess for the SIPLACE WPC on the disk.
CAUTION
No SIPLACE WPC
If no SIPLACE WPC is fitted, you will not be able to feed in components with a height of 40
mm.
The SIPLACE cover may not be converted if there is no WPC!
To do so, proceed as follows:
Fig.38: Cover with hinges
1. Cover
2. Hinges on the cover (2x)
 CAUTION!
You may need to enlist the help of a
second person for this job.
.
► Loosen the screws fastening the hinges
at the top of the cover. While doing this,
hold the front section of the cover tight.
► Remove the front section of the cover.
► Insert the new front section of the cover
into the machine and screw into place.
Fig.39: Label on the cover
1. Danger of crushing label (2x)
2. Barcode adhesive label
► Attach the following adhesive labels to
the new cover. For their exact posi-
tions, refer to the old cover.
3 Fitting the gantry
3.5 Installing the Gantry
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
119
3.5 Installing the Gantry
Fig.40: Moving the gantry in
► (1) Use the gantry lift to move the
gantry in front of the machine location.
 CAUTION!
Move the gantry carefully
Make sure that you do not hit the
gantry anywhere and do not move it
too far into the machine (2)
. Always
check the right and left sides.
.
Fig.41: Docking in at the gantry carrier
1. Docking hook on the gantry carrier
2. Docking unit on the machine linear
guides
► Move the gantry forwards so that the
gantry carrier docking hooks (1)
are in
front of the machine docking unit (2)
.
► Always check the right and left sides.
Hooking the gantry carrier into place on the machine
Fig.42: Lifting the gantry
► Lift the gantry so that the gantry carrier
docking hooks (1)
are above the
machine docking unit (2)
.
► Carefully lower the gantry so that the
two docking hooks (1)
slide reliably into
the openings in the docking unit (2)
.
► Always check the right and left sides.