3 Fitting the gantry 3.7 Final Work Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal Reconfiguration Kit Twin VHF with Gantry 06/2020 131 Fig.65: Gantry with TH->com…

3 Fitting the gantry
3.7 Final Work
130 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
3.7.8 Performing Calibration
NOTICE
Information about mapping
For details of mapping, such as the allocation of mapping plates to machine types, see the
technical information "Information about Mapping" [DE:TI2017‑10D04]
[EN:TI2017‑10E04].
Overview
The calibration divides the mapping data and then merges them during the gantry upgrade. In most
cases this means that only a brief calibration procedure needs to be performed (see Fast Hardware
Exchange and flow diagram).
If gantry 1 is fitted, you need to perform PCB/component mapping with the glass plate, irrespective
of the head configuration (gantry 1 is the master gantry).
NOTICE
TwinHead gantry at location 2
If there is a TwinHead gantry fitted at location 2 (gantry 2), the PCB mapping data must be
present. Component mapping can then be performed using the aluminum plate. It is advis-
able to perform a complete PCB/component mapping!
NOTICE
Long Board Option (LBO)
If a gantry is installed on a machine with LBO, this gantry has to be mapped using the Map-
ping with LBO button.
Fig.64: PCB/component mapping

3 Fitting the gantry
3.7 Final Work
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
131
Fig.65: Gantry with TH->component mapping
Confirming the autoconfiguration (SW 713.x)
Fig.66: Select operator level
► Select the button.
► Select the button.
► Switch over to the operator level Ma-
chine service.
ð The button will be shown.

3 Fitting the gantry
3.7 Final Work
132 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
Fig.67: Service menu
► Select Automatic Calibration.
Fig.68: Calibration
► Go to Combined steps and select the
items Main axes calibration
and Cali-
bration of fiducials, cameras and
heads.
► Select the gantry.
► Select Next and follow the instruction
on the screen.
3.7.8.1 eSW Download (SW 70x)
Fig.69: Select operator level
► Select the button.
► Select the button.
► Switch over to the operator level Ma-
chine service.
ð The button will be shown.