00198783-01_AI_Kit_TwinVHF_Gantry_SXV3_de_en.pdf - 第122页

3 Fitting the gantry 3.5 Installing the Gantry 122 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal Reconfiguration Kit Twin VHF with Gantry 06/2020 Buffer types Fig.48…

100%1 / 152
3 Fitting the gantry
3.5 Installing the Gantry
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
121
Fig.46: Flat ribbon cable and pneumatic connections
Carefully place the flat ribbon cable (1)
and the pneumatic connections (2) over
the gantry.
Remove the black plastic foil. A cable
tie fixes the black plastic foil to the trail-
ing cable(3)
.
3.5.1 Replacing/Fitting the End Position Buffers
Overview
Fig.47: Upgrade to SIPLACE SX2
1. Location 1
2. Location 2
3. Safety switch
4. Buffer with distance pipe at a SIPLACE
SX1
Standard: 226.5 mm
Twin VHF: 174 mm
5. Short buffer on an SX2 (standard and
Twin VHF)
When upgrading from a SIPLACE SX1 to a SIPLACE SX2, you need to fit the short end position
buffers at location 2.
When downgrading from a SIPLACE SX2 to a SIPLACE SX1, fit the buffer with distance pipe at
location 2.
When fitting a 40mm gantry, you need to fit the buffer with distance pipe at location 2 of the
SIPLACE SX1. (Buffer labeling: "LOC2,VHFSX1").
3 Fitting the gantry
3.5 Installing the Gantry
122 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
Buffer types
Fig.48: Buffer types
1. Standard: long buffer with distance pipe
for location 2 of an SX1 (226.5mm)
2. Twin VHF: buffer with shortened dis-
tance pipe [03105259-xx] for location 2
of an SX1 (174mm)
Buffer labeling: "LOC2, VHF SX1
"
3. Standard and Twin VHF: short buffer
with rubber damper for both locations
on an SX2 (35mm)
Machine SIPLACE SX1 SIPLACE SX2
Location 1 Location 2 Location 1 Location 2
Standard 35 mm rubber
dampers
226.5 mm
distance pipe
35 mm rubber
dampers
35 mm rubber
dampers
40 mm gantry for
Twin VHF
35 mm rubber
dampers
174 mm distance
pipe (shortened)
LOC2, VHF SX1
35 mm rubber
dampers
35 mm rubber
dampers
Installation
NOTICE
Holder and distance pipe
You might need to fit the holder from one distance pipe onto the other distance pipe.
When doing so, hand-tighten
the distance pipe on the holder.
Fig.49: Fitting the end position buffer
Fit the end position buffer (2) to the left
side.
Fit the end position buffer (3) to the
right side. The safety switch (4)
for the
buffer monitoring function must engage
in the Schmersal switch.
Tighten the fastening screws (1) for the
buffers with a torque of 14Nm
.
3 Fitting the gantry
3.6 Connecting the Trailing Cable
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
123
3.6 Connecting the Trailing Cable
Fig.50: Cover
Remove the cover (1) over the gantry
interface. To do this, remove the two
fastening screws on the right side and
carefully open the bottom left pushbut-
ton.
Fig.51: Fitting the trailing cable
Fit the trailing cable holder (1) from
below, to the gantry distributor holder.
See the following section.
Carefully place the flat ribbon cable and
the pneumatic hoses to one side (2)
.
Make sure you do not damage the
cables and hoses.
Take care that the alignment is correct
and that all cables and hoses are run
above one another and evenly.
 NOTICE!
Use the correct gantry with Gig E trail-
ing cable, since only this can be con-
nected as described. It is not possible
to connect an older gantry with hotlink
trailing cable.
.
Fig.52: Heat-shrinkable hose
 NOTICE!
When fitting the trailing cable, make
sure that the heat-shrinkable sleeve
(1) protects the flat ribbon cable under
the Y sensor module holder.
.