00198783-01_AI_Kit_TwinVHF_Gantry_SXV3_de_en.pdf - 第108页

3 Fitting the gantry 3.1 Preparations at the Machine 108 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal Reconfiguration Kit Twin VHF with Gantry 06/2020 3.1.4 Removing…

100%1 / 152
3 Fitting the gantry
3.1 Preparations at the Machine
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
107
3 Fitting the gantry
NOTICE
Exemplary description
This manual describes the upgrading of gantry 2 at location 2. The assembly of gantry 1 is
the same. The diagrams sometimes show standard gantries as an example. You should
still perform the tasks described. Any differences will be explicitly indicated.
NOTICE
Mapping
When upgrading gantry 1 (master gantry) at location 1, component board mapping must be
performed after the assembly.
► Observe the technical information "Information about mapping" [DE:TI2017‑10D04]
[EN:TI2017‑10E04].
3.1 Preparations at the Machine
3.1.1 Fitting the Stationary Camera
If not already present, you will need to fit a stationary camera.
► Refer to the appropriate assembly instructions:
– Assembly instructions "SIPLACE X-Series S, SX-Series V3 stationary camera type 25/33
(GigE)" [DEEN:00197710‑xx]
3.1.2 Removing the Gantry
► If you need to remove an existing gantry before installation, read the assembly instructions
"Gantry modularity SX1/SX2 V3" [00198705-xx] (English/German).
3.1.3 Opening the Covers
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}85]
Fig.20: Overview of protective cover
► Open the protective cover at location 2
and move the component trolley out of
the machine.
► Loosen the two screws (2) fastening
the side covers (1)
on the right and left.
► Open the two covers (1).
3 Fitting the gantry
3.1 Preparations at the Machine
108 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
3.1.4 Removing the End Position Buffer
The long end position buffers must be fitted in SIPLACE SX1 machines with one gantry. When con-
verting a SIPLACE SX1 to an SX2, you need to remove this and replace it with short end position
buffers.
Fig.21: Long end position buffer
Remove the two long end position buffers.
After fitting the second gantry, fit the two
short end position buffers in place of the
long ones.
► Loosen the fastening screw (2) on the
long end position buffer (1)
.
► Remove the two end position buffers
from the right and left sides.
 NOTICE!
Keep the two long end position buffers
in the "Prepared" case for fitting back
into place later on.
.
3.1.5 Preparing the Trailing Cable
Overview
Fig.22: Trailing cable, packed
The trailing cable (1) is packed in black
plastic foil and fixed to a holder(2)
.
3 Fitting the gantry
3.1 Preparations at the Machine
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 V3 Reconfiguration Kit Twin VHF mit Portal
Reconfiguration Kit Twin VHF with Gantry 06/2020
109
Loosening the trailing cable
Fig.23: Trailing cable in holder
► Loose the fixture screw (1) on the
holder (2)
.
► Carefully disconnect the trailing cable
(3)
from its holder.
 CAUTION!
Take care when handling the trailing
cable!
Take care not to damage the foil or the
trailing cable.
.
► Place the holder and the fixture screw
in the "Prepared case" for fitting back
into place later on.
Fig.24: Trailing cable in the machine
► Take the trailing cable (1) and place it
carefully towards the front, into the
machine.