N7201A654E.pdf - 第120页
NPM- TT2 EJM1EE-MB-02 T-02 APC-MFB: LNB process error Error Messag e Troubleshooting 2-1-3 Single stop errors 25 Error Code Error Message Cause Inspection and Solution In LNB^ error occurred in other company AOI check re…

NPM-TT2 EJM1EE-MB-02T-02
Load measure result NG
Tape guide recognition
error
Tape guide mismatch
Tape setting incomplete
Tray abnormal
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Although the action is
requested to the tray feeder^
the action can't be executed
because the error is
notifiedfrom the tray feeder.
(Tray abnormal)
Please confirm the tray feeder status.
40474
Tape setting isn't completed
in specified time.
(Single stop error occurred.)
Please set the new tape from the
beginning.
40475
The kind of tape guide which
is set is different from the
recommended tape guide of
using parts.
(Single stop error occurred.)
Please confirm the set tape guide
kind.
40476
Failed in tape guide
recognition.
(Single stop error occurred.)
Please confirm the set tape guide
status.
40477
Mount load measure result
has exceeded NG range.
(Mount load measure result
NG)
Please confirm the nozzle status.
40479
2-1-3-48

NPM-TT2 EJM1EE-MB-02T-02
APC-MFB:
LNB process error
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 25
Error Code
Error Message
Cause Inspection and Solution
In LNB^ error occurred in
other company AOI check
result file convert process.
1:Data out of range 2:No
applicable parts error 3:File
format error(AOI check
result) 4:File format
error(NPM production data)
5:File access error^ other
(Single stop error occurred.)
・Error1,3Please confirm the
situation of the error occurred and
contact the AOI maker.・
Error21)Please confirm that NPM
and AOI production data are same
product.
2)Please confirm if the parts that is
not in the NPM production data
isn't checked by AOI.(Confirm
match of parts pattern number,
circuit number)
3)Please confirm the situation of the
error occurred and contact PFSC.・
Error4Please confirm the situation
of the error occurred and contact
PFSC.・Error51)Please confirm the
communication status between
LNB and AOI.2)Please confirm the
situation of the error occurred and
contact PFSC.
40484
2-1-3-49

NPM-TT2 EJM1EE-MB-02T-02
Ionizer Alarm
Constant check error
APC-MFB:
File I/O error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in MFB
related file input and output
process.(Display the kind of
the following error) 1:Data
out of range 2:No applicable
parts error 3:File format
error(AOI check result)
4:File format error(NPM
mount position correct
record ) 5:File access error^
other
(Single stop error occurred.)
・Error1,2,3,4Please confirm the
situation of the error occurred and
contact PFSC.・Error51)Please
confirm the communication status
between LNB and MC.
2)Please confirm the situation of the
error occurred and contact PFSC.
40485
Error occurred in the
constant check action.
(Single stop error occurred.)
1)Please confirm the constant
checker unit or parts status.
2)Please confirm if the set parts is
correct constant parts.
40486
Detected the ionizer alarm.
(Single stop error occurred.)
Please settle the problem of ionizer
alarm and resume the production.
40488
2-1-3-50