N7201A654E.pdf - 第65页

NPM- TT2 EJM1EE-MB-02 T-02 Supply B Cover Open Magazine B Cover Open Solutions to errors Error Code Error Message Cause Inspection and Solution Magazine door is open. (Self-di agnosis erro r occurred. ) Take measures in …

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Tray B Control Board Fuse
Disconnection
Tray B Control Board
Temperature Error
Tray B Control Board
Voltage Error
3-Nozzle Head PCB Fuse
Disconnection
3-Nozzle Head PCB
Temperature Error
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 20
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 3-
nozzle mount head control
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40125
Fuse of the 3-nozzle mount
head control board has
blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40126
Voltage at the tray control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40127
CPU temperature at the tray
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40128
Fuse of the tray control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40129
2-1-2-39
NPM-TT2 EJM1EE-MB-02T-02
Supply B Cover Open
Magazine B Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Magazine door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40130
Supply door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40131
2-1-2-40
NPM-TT2 EJM1EE-MB-02T-02
Safety Relay Reset is
abnormal.
Opposing Y Axis Posi
Error(Opposing Supply No
Exist)
Opposing Y Axis Posi
Error(Opposing Supply
Exist)
Ceiling Fan2 Error
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 21
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with obstacles.
2) Make sure there is no
disconnected wire.
40132
Opposite XY unit stopped
within the range of the XY
unit.
(Self-diagnosis error
occurred.)
Move the opposite XY unit close to
the origin position manually.
40133
Opposite XY unit are out of
the turnout position.
(Self-diagnosis error
occurred.)
Move the opposite XY unit to the
turnout position manually.White
label is attached on the Y-axis as
the turnout position.Make sure that
the end of the XY unit falls within the
white label.
40134
Safety relay reset error
occurred. Since the safety
cover was opened for a
moment^ the safety relay
cannot be reset.
(Self-diagnosis error
occurred.)
Widely open the front or rear safety
cover once and then close it.
40135
2-1-2-41