N7201A654E.pdf - 第44页
NPM- TT2 EJM1EE-MB-02 T-02 12-nozzle hea d Z PCB Voltage Error Unknown Unit Detectio n (Option lamp) Unknown Unit Detectio n (Height sensor) Error Messag e Troubleshooting 2-1-2 Self-diagnosis errors 10 Error Code Error …

NPM-TT2 EJM1EE-MB-02T-02
Unknown Unit Detection
(Comp thickness sensor)
Unknown Unit Detection
(Changer)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Changer cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the changer is set
properly to the feeder carriage.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the changer. If
the error persists, contact PFSC.
40045
Component thickness sensor
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the component
thickness sensor is set properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the component
thickness sensor. If the error
persists, contact PFSC.
40046
2-1-2-18

NPM-TT2 EJM1EE-MB-02T-02
12-nozzle head
Z PCB Voltage Error
Unknown Unit Detection
(Option lamp)
Unknown Unit Detection
(Height sensor)
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 10
Error Code
Error Message
Cause Inspection and Solution
Height measurement sensor
cannot be detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the height
measurement sensor is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and make sure the
unit is installed to the height
measurement sensor. If the error
persists, contact PFSC.
40047
Option light cannot be
detected.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Make sure the option light is set
properly.
2) Choose [Machine] - [Information]
- [PnP] - [List] and check that the
option light is installed. If the error
persists, contact PFSC.
40048
Voltage at the 12-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40049
2-1-2-19

NPM-TT2 EJM1EE-MB-02T-02
12-Nozzle Head
θPCB Fuse Disconnection
12-Nozzle Head
θPCB Temperature Error
12-Nozzle Head
θPCB Voltage Error
12-Nozzle Head
Z PCB Fuse
Disconnection
12-Nozzle Head
Z PCB Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 12-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40050
Fuse of the 12-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40051
Voltage at the 12-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40052
CPU temperature at the 12-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40053
Fuse of the 12-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40054
2-1-2-20