N7201A654E.pdf - 第241页

NPM- TT2 EJM1EE-MB-02 T-02 Communication : FROM Mode Switch Error Communication : FROM Delete Error Communication Error Controller No Res ponse Solutions to errors Error Code Error Message Cause Inspection and Solution E…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Driver Alarm: Encoder
Disconnect
Driver Alarm: Motor
Disconnect
Driver Alarm: Excess
Voltage
Driver Alarm: EMG Input
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 35
Error Code
Error Message
Cause Inspection and Solution
Because of emergency stop
error^driver error was
detected. Safety cover is
opened^Transfer opening
sensor ON^etc.
(Driver alarm detected.)
Check the error caused by
emergency stop. Safety cover is
opened,Transfer opening sensor
ON,etc.
1767
Abnormal current flowed to
the output line of the motor. It
may damage the driver or
cause ground fault of the
cable.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1768
Output line to the motor has
broken while the motor is
stopped.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1769
Encoder cable of the motor
has broken or the motor
encoder has been damaged.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1770
2-1-4-68
NPM-TT2 EJM1EE-MB-02T-02
Communication: FROM
Mode Switch Error
Communication: FROM
Delete Error
Communication Error
Controller No Response
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1771
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1772
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1773
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1774
2-1-4-69
NPM-TT2 EJM1EE-MB-02T-02
Communication:
Argument Error
Communication: Memory
Error
Communication: Data
Transfer Error
Communication: Address
Setting Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 36
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1775
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1776
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1777
Error occurred in
communication with the
motor.
(No response from
controller.)
Check the situation of the error
occurred and error message, and
contact PFSC. If the red LED on the
motor is flashing, count the flashes.
1778
2-1-4-70