N7201A654E.pdf - 第278页
NPM- TT2 EJM1EE-MB-02 T-02 Undefined Axis O peration Status Setting Undefined Shutter Setting Undefined Axis Setting Supply Finish Monitor Abnormality Error Messag e Troubleshooting 2-1-4 Emergency stop errors 54 Error C…

NPM-TT2 EJM1EE-MB-02T-02
Tray Counter Abnormality
Pick-up Section Pallet
Number Setting Error
Supply Section Pallet
Number Setting Error
Speed Number Out of
Range
Command Issue in
Executing
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Another movement
command was issued while a
movement command was
being executed.
(Command issue error
occurred during execution.)
Check the situation of the error
occurred and error message, and
contact PFSC.
2152
Moving speed of the tray
data is abnormal.
(Speed No. out of range
error occurred.)
Make sure there is nothing wrong
with the tray data.If the error
persists, check the situation of the
error occurred and error message,
and contact PFSC.
2153
Invalid pallet number.
(Feeder pallet No. setting
error occurred.)
Set the pallet number of the feeder
carriage on the pallet position check
screen.
2154
Invalid pallet number.
(Pickup pallet No. setting
error occurred.)
Set the pallet number of the feeder
carriage on the pallet position check
screen.
2155
Invalid value set in the tray
counter.
(Tray counter error occurred.)
Set a proper tray counter value on
the tray arrangement screen.
2156
2-1-4-105

NPM-TT2 EJM1EE-MB-02T-02
Undefined Axis Operation
Status Setting
Undefined Shutter Setting
Undefined Axis Setting
Supply Finish Monitor
Abnormality
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 54
Error Code
Error Message
Cause Inspection and Solution
Error occurred in the Supply
Complete switch monitoring
processing of the tray feeder.
(Supply completion monitor
error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2157
Wrong axis command was
issued to the tray.
(Undefined axis error
occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2158
Undefined shutter motion
command to the tray was
issued.
(Undefined shutter
designation error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2159
Axis error occurred but the
cause cannot be identified.
(Undefined axis motion
designation error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2160
2-1-4-106

NPM-TT2 EJM1EE-MB-02T-02
Undefined XY Unit Setting
Undefined Tray Status
Setting
Undefined Pallet No.
Setting
Undefined Speed Setting
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Undefined axis speed type
(other than max. frequency^
acceleration time^ self-start
frequency) was specified for
the tray.
(Undefined speed
designation error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2161
Pallet No. outside the range
has been specified.
(Undefined pallet No.
designation error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2162
Undefined tray operation
mode is engaged.
(Undefined tray designation
error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2163
Undefined XY unit have been
specified.
(Undefined XY-unit
designation error occurred.)
Close the error screen and restart
production.If the error persists,
check the situation of the error
occurred and error message, and
contact PFSC.
2164
2-1-4-107