NPM- TT2 EJM1EE-MB-02 T-02 Error Message Troubleshooting 2-2 W ar ning messa ge 3 Code Message Cause Solution Free arrange sequence change A process of feeder free arrangement is executed. A feeder is set to the feeder a…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Solutions to errors
Code
Message
Cause Solution
2-2-3
Bad head set
It is displayed when an head
is set as a bad head on the
bad head setting screen.
1.Check the bad head conditions.
2.After the problem has been
resolved, cancel the bad head
settings on the bad head setting
screen.
4037
Syringe trans empty
warn
Transfer material becomes
short.
Supply the transfer material.
5211
Can't measure cart
height
Failed to measure the cart
height.
The cart height cannot be
measured properly because
the nozzle installed to the
measurement head gets
clogged.
Check clogging of the nozzle
installed to the measurement head.
5225
No PCB warp measure
height.
It is displayed in the following
cases:
When “PCB warpage
detection” of software
switch in the production
data is set to “ON” and
“Height sensor” of the
option setting is set to
“OFF”.
When “PCB warpage
detection” is “ON” and
“Height sensor” of the
option setting is “None”.
Confirm the production data and
details of the optional settings.
5668
NPM-TT2 EJM1EE-MB-02T-02
Error
Message
Troubleshooting
2-2
Warning message 3
Code
Message
Cause Solution
Free arrange sequence
change
A process of feeder free
arrangement is executed.
A feeder is set to the feeder
address which is not
specified by the production
data, and production
continues.
To disable an feeder free
arrangement operation, set the
feeder again according to the
production data.
5798
Feeder reset SW
The feeder reset switch has
been detected.
Because pickup of the
applicable feeder is not
performed (skipped), the
feeder can be pulled out.
Pull out the feeder, and confirm the
feeder state and replenish parts.
5815
No PCB warp
correction
It is displayed in the following
cases:
When “PCB warpage
detection” of software
switch in the production
data is set to “ON” and
“PCB warpage correction”
of the option setting is set
to “OFF”.
When “PCB warpage
information receipt” of the
communication setting is
set to “ON” and “PCB
warpage correction” of the
option setting is set to
“OFF”.
Confirm the production data and
details of the optional settings.
5918
Feeder firm Version
Warning
The feeder firmware version
does not match the machine
software version.
Upgrade the feeder firmware
version.
6133
2-2-4