N7201A654E.pdf - 第200页
NPM- TT2 EJM1EE-MB-02 T-02 Data Set Command Not Issued Error Write EEPROM Error Servo Ready Off Completion Error Interrupt Error Messag e Troubleshooting 2-1-4 Emergency stop errors 15 Error Code Error Message Cause Insp…

NPM-TT2 EJM1EE-MB-02T-02
Position Error Interrupt
Exclusive Process Error
Return To Origin Process
Error
Motion Process Error
Motion Preparation Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Servo driver of the target axis
is at fault.
(Operation preparation error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1525
Servo driver of the target axis
is at fault.
(Operation process error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1526
Servo driver^ motor or origin
sensor of the target axis is at
fault.
(Origin return process error
occurred)
Check the situation of the error
occurred and error message, and
contact PFSC.
1527
Servo driver of the target axis
is at fault.
(Exclusive process error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1528
Unwanted interrupt occurred
during positioning of XY unit.
(Position interrupt error
occurred.)
1) Restart the machine.
2) If the error persists, contact PFSC.
1529
2-1-4-27

NPM-TT2 EJM1EE-MB-02T-02
Data Set Command Not
Issued Error
Write EEPROM Error
Servo Ready Off
Completion Error Interrupt
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 15
Error Code
Error Message
Cause Inspection and Solution
Unwanted interrupt occurred
during positioning of XY unit.
(Completion interrupt error
occurred)
1) Restart the machine.
2) If the error persists, contact PFSC.
1530
Axis movement failed
because it was attempted
without the communication
with the servo amplifier
established.
(Servo ready OFF error
occurred.)
Restart the machine.If the error
persists even after the machine is
restarted, contact PFSC.
1531
Wiring between the main
controller and servo amplifier
may be broken.
(Writing to EEPROM in servo
amplifier failed to finish
properly.)
Make sure the wiring between the
main controller and servo amplifier
is not broken.
1541
Improper procedure was
taken in software processing.
(Axis movement failed due to
incorrect data of the
applicable axis (mismatch of
data combination).)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1542
2-1-4-28

NPM-TT2 EJM1EE-MB-02T-02
Emergency Stop
Deceleration Error
Error Deceleration Error
Acceleration Command
Error
Speed Command Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis speed.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1543
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis acceleration.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1544
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis deceleration for error
stop.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1545
Improper procedure was
taken in software processing.
(Axis movement failed
because of zero set for the
axis deceleration for
emergency stop.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1546
2-1-4-29