N7201A654E.pdf - 第263页
NPM- TT2 EJM1EE-MB-02 T-02 System state error Command error IspBox MainSys APC- MFB file make error IspBox SubSys Sample image save error IspBox take image start timeout Solutions to errors Error Code Error Message Cause…

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys PCB skip
notification command
error
Camera IF board DMA
transfer error
Camera IF board
Exposure finish
information deal error
Camera IF board
Exposure finish
information start error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 46
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to set the exposure
completion notice of the
camera IF board.)
Restart the machine. If the error
persists, contact PFSC.
1906
Exposure finish information
could not be received.
(Failed to receive the
exposure completion notice
of the camera IF board.)
Check the connection of the camera
link cable.
1907
Image transfer from the
camera IF board to the
inspection box PC failed.
(Failed in DMA transfer of
image from the camera IF
board.)
Check the connection of the camera
link cable.
1908
Improper procedure was
taken in software processing.
(PCB skip information
command notified
incorrectly.)
Restart the machine. If the error
persists, contact PFSC.
1909
2-1-4-90

NPM-TT2 EJM1EE-MB-02T-02
System state error
Command error
IspBox MainSys APC-
MFB file make error
IspBox SubSys Sample
image save error
IspBox take image start
timeout
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Because the IspBOX
process is delayed^ it has
been over the specified time
at the start of taking image.
(Image is taken in inspect
head after the light is off.)
Please restart the auto running. If
the error persists, contact PFSC.
1910
Needful image data lost in
saving sample image.
(Failed to save the sample
image.)
It is possible that the recognition is
wrong in the mark recognition
process.Please confirm the mark
recognition process.
1911
(1)Can't communicate with
the LNB.(2)The remain
capacity of the hard disk is
not enough.(3)The file
system is in a incorrect
situation.
(Failed to make the APC-
MFB file.)
(1)Please confirm connection to the
network.(2)Please confirm the
remain capacity of the hard disk on
IspBox and LNB.Then restart the
machine.If it happened again.
Please inform the manufacturer.
1912
VLC system may be at fault.
(Command error detected by
VLC.)
Contact PFSC.
1951
VLC system may be at fault.
(System error detected by
VLC.)
Contact PFSC.
1952
2-1-4-91

NPM-TT2 EJM1EE-MB-02T-02
Low light intensity
Effective Section overflow
Line number overflow
Sensor Blocked
completely
Communication error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 47
Error Code
Error Message
Cause Inspection and Solution
Connector may be
disconnected.
(Communication error
detected by VLC.)
Check the connection connector.
1953
1) Sensor is blocked
completely by some
obstacles.
2) Connector may be
disconnected.
(VLC sensor blocked
completely.)
1) Remove any obstacles. Wipe
away any dirt from the lens if it is
dirty.
2) Check the connector.
1954
VLC system may be at fault.
(Line overflow detected by
VLC.)
Contact PFSC.
1955
VLC system may be at fault.
(Overflow from effective zone
detected by VLC.)
Contact PFSC.
1956
Lens may be dirty.
(Drop in intensity detected by
VLC.)
Clean the lens if dirt is found.
1957
2-1-4-92