NPM- TT2 EJM1EE-MB-02 T-02 Timeout Error Command processing error Over Current Anomaly(R) Encoder Dis connect Anomaly(R) Solutions to errors Error Code Error Message Cause Inspection and Solution Invalid motor encoder va…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Overload Anomaly(R)
Over Current Anomaly(L)
Encoder Disconnect
Anomaly(L)
Overload Anomaly(L)
Origin Return Abnormality
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 29
Error Code
Error Message
Cause Inspection and Solution
Origin return failed to be
completed within the
prescribed time and timeout
occurred.
(Head axis did not properly
return to origin. )
Check the situation of the error
occurred and error message, and
contact PFSC.
1707
Positional deviation with
power ON or integrated
current is beyond the
specified value.
(Head movement stopped
due to overload.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1708
Invalid motor encoder value.
(Head movement stopped.)
Check the connection between the
head motor and control board inside
the head and restart production.
Then, check the situation of the
error occurred and error message,
and contact PFSC.
1709
Current exceeding the
specified value has flown
during head movement.
(Abnormal voltage of current
was supplied to the head
motor.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1710
Positional deviation with
power ON or integrated
current is beyond the
specified value.
(Head movement stopped
due to overload.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1711
2-1-4-56
NPM-TT2 EJM1EE-MB-02T-02
Timeout Error
Command processing
error
Over Current Anomaly(R)
Encoder Disconnect
Anomaly(R)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Invalid motor encoder value.
(Head movement stopped.)
Check the connection between the
head motor and control board inside
the head and restart production.
Then, check the situation of the
error occurred and error message,
and contact PFSC.
1712
Current exceeding the
specified value has flown
during head movement.
(Abnormal voltage of current
was supplied to the head
motor.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1713
Communication error
occurred between the driver
and host. Cable between the
head motor and driver may
be broken.
(Error occurred in command
processing.)
Check the situation of the error
occurred and error message, and
contact PFSC.
1714
No response from the head
or feeder cart^ etc.
(Communication timeout
error occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1715
2-1-4-57
NPM-TT2 EJM1EE-MB-02T-02
Communication: FROM
Delete Error
Communication Error
Check Sum Error
Head No. Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 30
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart^ etc.
(Communication failure)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1716
Check sum error occurred in
the communication data from
the head or feeder cart^ etc.
to the host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1717
Improper procedure was
taken in software processing.
(Communication error
occurred.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1718
Improper procedure was
taken in software processing.
(Failed to clear FROM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1719
2-1-4-58