NPM- TT2 EJM1EE-MB-02 T-02 DC power FAN alarm Solutions to errors Error Code Error Message Cause Inspection and Solution Fan of the DC power stopped. (Self-di agnosis erro r occurred. ) Take any of the following measures…

NPM-TT2 EJM1EE-MB-02T-02
Multi Recog Camera FAN
alarm
Multi Recog Cam
temperature warning
Multi Recog Cam voltage
warning
LW16-Nozzle HeadθPCB
Fuse Disconnection
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 23
Error Code
Error Message
Cause Inspection and Solution
Fuse of the LW16-nozzle
mount head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40163
Voltage at the multi recog
camera control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40164
CPU temperature at the multi
recog camera control board
has exceeded the setting
value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40165
Fan of the multi recog
camera stopped.
(Self-diagnosis error
occurred.)
Because obstacle interfere with the
fan of multi recognition camera
inside or the fan at fault, please
contact PFSC.
40166
2-1-2-45

NPM-TT2 EJM1EE-MB-02T-02
DC power FAN alarm
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fan of the DC power
stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with wiring, etc.
2) Make sure there is no
disconnected wire.
40167
2-1-2-46

NPM-TT2 EJM1EE-MB-02T-02
Part Pickup Error
Stock Parts Empty
Parts Empty Stop
Parts Empty Occurs
Parts Empty Warning
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 1
Error Code
Error Message
Cause Inspection and Solution
Components are running
short.
(Single stop error occurred.)
Supply the components.
40302
Components have run out.
(Single stop error occurred.)
Supply the components.
40303
Components have run out.
(Single stop error occurred.)
Supply the components.
40304
Stocked components have
run out.
(Single stop error occurred.)
Supply the components.
40305
Any of the following causes
is likely:
1) Invalid component data
height.
2) Improper component feed.
3) Incorrect pickup position.
(Single stop error occurred.)
Take measures shown with the
same number as that of the cause.
1) Correct the component data.
2) Replace the feeder.
3) Choose [Arrange] - [Parts
prepare] - [Feeder] - [Pickup
position] and perform teaching of
the component pickup position.
40306
2-1-3-1