N7201A654E.pdf - 第232页

NPM- TT2 EJM1EE-MB-02 T-02 Communication : Head Communication Part Answer Error Communication : Command Enable Invalid Error Communication : Semaphore Error Communication : File Open Error Communication : Data Write Erro…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Communication: Memory
Allocation Error
Communication: Address
Setting Error
Communication: FRAM
Read Error
Communication: FRAM
Write Error
Communication: FROM
Mode Switch Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to switch to FROM
mode.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1720
Improper procedure was
taken in software processing.
(Failed to write data to
FRAM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1721
Improper procedure was
taken in software processing.
(Failed to read data from
FRAM.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1722
Improper procedure was
taken in software processing.
(Failed to set communication
address.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1723
Improper procedure was
taken in software processing.
(Failed to secure memory.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1724
2-1-4-59
NPM-TT2 EJM1EE-MB-02T-02
Communication: Head
Communication Part
Answer Error
Communication:
Command Enable Invalid
Error
Communication:
Semaphore Error
Communication: File Open
Error
Communication: Data
Write Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 31
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to write data.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1725
Improper procedure was
taken in software processing.
(Failed to open file.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1726
Improper procedure was
taken in software processing.
(Failed to control software.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1727
Improper procedure was
taken in software processing.
(Failed to disable enable
command.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1728
Interrupt occurred to get
module errors.
(Error in connection module
like head^ feeder cart or
tray.)
Take measures according to the
error information of the module that
issues error interruption.
1729
2-1-4-60
NPM-TT2 EJM1EE-MB-02T-02
Communication: Data
Length Error
Communication: Hand
Shake Error
Communication:
Communication Default
Unconnected Error
Communication: Head
Communication Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1730
Connection module
connected to the machine
failed to be detected.
(Communication error
occurred.)
Check the connection of the feeder
cart.
1731
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1732
Improper procedure was
taken in software processing.
(Invalid data length found in
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1733
2-1-4-61