N7201A654E.pdf - 第46页

NPM- TT2 EJM1EE-MB-02 T-02 8-Nozzle Head θ PCB Temper ature Error 8-Nozzle Head θ PCB Voltage Error 8-Nozzle Head Z PCB Fuse Disco nnection 8-Nozzle Head Z PCB Temperature Error 8-Nozzle Head Z PCB Voltage Error Error Me…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
12-Nozzle Head
θPCB Fuse Disconnection
12-Nozzle Head
θPCB Temperature Error
12-Nozzle Head
θPCB Voltage Error
12-Nozzle Head
Z PCB Fuse
Disconnection
12-Nozzle Head
Z PCB Temperature Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
CPU temperature at the 12-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40050
Fuse of the 12-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40051
Voltage at the 12-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40052
CPU temperature at the 12-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40053
Fuse of the 12-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40054
2-1-2-20
NPM-TT2 EJM1EE-MB-02T-02
8-Nozzle Head
θ PCB Temperature Error
8-Nozzle Head
θ PCB Voltage Error
8-Nozzle Head
Z PCB Fuse
Disconnection
8-Nozzle Head
Z PCB Temperature Error
8-Nozzle Head
Z PCB Voltage Error
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 11
Error Code
Error Message
Cause Inspection and Solution
Voltage at the 8-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40055
CPU temperature at the 8-
nozzle mount head Z-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40056
Fuse of the 8-nozzle mount
head Z-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40057
Voltage at the 8-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40058
CPU temperature at the 8-
nozzle mount head θ-axis
control board has exceeded
the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40059
2-1-2-21
NPM-TT2 EJM1EE-MB-02T-02
2-Nozzle Dispense Head
Z PCB Voltage Error
2-Nozzle Head
PCB Fuse Disconnection
2-Nozzle Head
PCB Temperature Error
2-Nozzle Head
PCB Voltage Error
8-Nozzle Head
θ PCB Fuse
Disconnection
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Fuse of the 8-nozzle mount
head θ-axis control board
has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40060
Voltage at the 2-nozzle
mount head control board
has dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40061
CPU temperature at the 2-
nozzle mount head control
board has exceeded the
setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40062
Fuse of the 2-nozzle mount
head control board has
blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40063
Voltage at the 2-nozzle
dispense head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Make sure there is nothing wrong
with electrical wiring.
40064
2-1-2-22