NPM- TT2 EJM1EE-MB-02 T-02 Safety Relay Reset is abnormal. Opposing Y Axis Posi Error(Opposing Supply No Exist) Opposing Y Axis Posi Error(Opposing Supply Exist) Ceiling Fan2 Error Error Messag e Troubleshooting 2-1-2 Se…

NPM-TT2 EJM1EE-MB-02T-02
Supply B Cover Open
Magazine B Cover Open
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Magazine door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40130
Supply door is open.
(Self-diagnosis error
occurred.)
Take measures in the following
order.
1) Close the supply door if opened.
2) If the error persists, the limit
switch may be broken.
3) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check the
condition of the supply
door.ON :Door closedOFF:Door
open
40131
2-1-2-40

NPM-TT2 EJM1EE-MB-02T-02
Safety Relay Reset is
abnormal.
Opposing Y Axis Posi
Error(Opposing Supply No
Exist)
Opposing Y Axis Posi
Error(Opposing Supply
Exist)
Ceiling Fan2 Error
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 21
Error Code
Error Message
Cause Inspection and Solution
Ceiling fan stopped.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Check the fan for any
interference with obstacles.
2) Make sure there is no
disconnected wire.
40132
Opposite XY unit stopped
within the range of the XY
unit.
(Self-diagnosis error
occurred.)
Move the opposite XY unit close to
the origin position manually.
40133
Opposite XY unit are out of
the turnout position.
(Self-diagnosis error
occurred.)
Move the opposite XY unit to the
turnout position manually.White
label is attached on the Y-axis as
the turnout position.Make sure that
the end of the XY unit falls within the
white label.
40134
Safety relay reset error
occurred. Since the safety
cover was opened for a
moment^ the safety relay
cannot be reset.
(Self-diagnosis error
occurred.)
Widely open the front or rear safety
cover once and then close it.
40135
2-1-2-41

NPM-TT2 EJM1EE-MB-02T-02
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
2-1-2-42
Outside input single stop
error
PCB Vacuum Pump
Thermal Error
Any of the following causes
is likely:
1) Vacuum pump for
vacuum-holding PCB is at
fault.
2) Improper setting of
overcurrent protection for
the thermal relay
(Self-diagnosis error
occurred.)
Reset the thermal relay and choose
[Machine] - [Adjust] - [All] - [Output
confirm] to check the vacuum pump
for vacuum-holding PCB for proper
operation. If any problem is found,
contact PFSC.
40136
Single stop requested by the
special system developed by
the customer.
(Self-diagnosis error
occurred.)
Reset the request for single stop
from the customer's special system.
Choose [Machine] - [Adjust] - [All] -
[Input confirm] to check the input
status of single stop.