N7201A654E.pdf - 第239页

NPM- TT2 EJM1EE-MB-02 T-02 Driver Alarm: Abnormal Power Supply Voltage Driver Alarm: Motor Step Out Driver Alarm: Origin Return Error Driver Alarm: System Setting Uncompleted Solutions to errors Error Code Error Message …

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Command Execution Error
Driver initialization
incomplete
Feeder Information Get
Error
Feeder Preparation Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 34
Error Code
Error Message
Cause Inspection and Solution
Feeder did not properly
return to origin during feeder
initialization due to some
trouble.
(Feeder preparation error
occurred.)
Make sure the tape reel is not
caught somewhere and there is no
foreign body on the pickup part.
Remove the feeder once and insert
it again to reset.Feed the tape
manually with the feed button and
make sure the tape runs smoothly.
1757
Error occurred in
communication with the
feeder. Feeder information
pointer is indeterminate value.
(Error occurred in obtaining
feeder information.)
Pull out and insert the feeder. If the
error persists, contact PFSC.
1758
Failing in driver initialization.
(Driver initialization
incomplete occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
1761
Another command was
issued while the first
command was being
executed.
(Command execution
disabled error occurred.)
Check the connection cable
between the driver and controller.
1762
2-1-4-66
NPM-TT2 EJM1EE-MB-02T-02
Driver Alarm: Abnormal
Power Supply Voltage
Driver Alarm: Motor Step
Out
Driver Alarm: Origin
Return Error
Driver Alarm: System
Setting Uncompleted
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Invalid driver setting.
(Driver alarm detected.)
Check the connection cable
between the driver and controller.
1763
Origin return for width
adjustment not completed.
(Driver alarm detected.)
Origin sensor may be at fault, or the
axis may have interfered with
something during width adjustment.
Check if the sensor detects any
foreign body properly.
1764
Pulse motor rotated beyond
the step-out range.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
Check the sliding parts such as ball
screw for any foreign matter that
can cause step-out.
1765
Power voltage dropped or
the driver may be at fault.
(Driver alarm detected.)
Check the power voltage of the
driver.
1766
2-1-4-67
NPM-TT2 EJM1EE-MB-02T-02
Driver Alarm: Encoder
Disconnect
Driver Alarm: Motor
Disconnect
Driver Alarm: Excess
Voltage
Driver Alarm: EMG Input
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 35
Error Code
Error Message
Cause Inspection and Solution
Because of emergency stop
error^driver error was
detected. Safety cover is
opened^Transfer opening
sensor ON^etc.
(Driver alarm detected.)
Check the error caused by
emergency stop. Safety cover is
opened,Transfer opening sensor
ON,etc.
1767
Abnormal current flowed to
the output line of the motor. It
may damage the driver or
cause ground fault of the
cable.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1768
Output line to the motor has
broken while the motor is
stopped.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1769
Encoder cable of the motor
has broken or the motor
encoder has been damaged.
(Driver alarm detected.)
Check the connection cable
between the motor and driver.
1770
2-1-4-68