N7201A654E.pdf - 第178页

NPM- TT2 EJM1EE-MB-02 T-02 Servo Switch Off Error Messag e Troubleshooting 2-1-4 Emergency stop errors 4 Error Code Error Message Cause Inspection and Solution Servo switch is OFF. (Interlock occurred.) Take measures in …

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Feeder Pull-out Detect
(Rear)
Feeder Pull-out Detect
(Front)
Air Pressure Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Abnormal air pressure
(Interlock occurred.)
Take any of the following measures:
1)Please adjust the regulator when
the supplied air pressure is low.
Please refer to the operating
instruction(Maintenance
articles)about setting pressure.
2)If the air pressure detection
setting(Low limit setting) is too
high, error occurs. Please set the
air pressure detection value to
0.4MPa.
1312
Feeder was pulled out due to
a reason other than
component exhaust.
(Interlock occurred.)
Set the feeder again.
1313
Feeder was pulled out due to
a reason other than
component exhaust.
(Interlock occurred.)
Set the feeder again.
1314
2-1-4-5
NPM-TT2 EJM1EE-MB-02T-02
Servo Switch Off
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 4
Error Code
Error Message
Cause Inspection and Solution
Servo switch is OFF.
(Interlock occurred.)
Take measures in the following
order.
1) Turn the servo switch (One
position each at front side and rear
side) clockwise to turn it ON.
2) If the error persists even after the
servo switch is turned ON, the
switch may be broken.Contact
PFSC.
1315
2-1-4-6
NPM-TT2 EJM1EE-MB-02T-02
Tape cover detection4
(Front)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Tape cover sensor 4 is
blocked.
(Interlock occurred.)
Take any of the following measures:
1) Close the front cover of the tape
feeder.
2) Set the toggle lever of the tape
feeder properly.
3) Make sure that detection area of
the tape cover sensor is not
blocked by the cover tape or big
component.
4) Choose [Machine] - [Adjust] - [All]
- [Input confirm] and check that the
feeder opening sensor 4 of the
table is OFF when the light from
the emitter is blocked and ON
when the light from the emitter
reaches the detector. At this time,
make also sure that the green LED
is lit when the light from the emitter
is blocked and the green and red
LEDs are lit when the light from
the emitter reaches the detector.
1316
2-1-4-7