N7201A654E.pdf - 第154页

NPM- TT2 EJM1EE-MB-02 T-02 Parts Re cognition Error Parts Re cognition Error Error Messag e Troubleshooting 2-1-3 Single stop errors 42 Error Code Error Message Cause Inspection and Solution Invalid brightness of detecte…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Parts Recognition Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
The state which is measured
by 3D sensor is abnormal.
Lead float and ball
collapse.The level state of
parts all is abnormal.
(Recognition error Electrode
Part or Parts All Height
(Float) Abnormal)
1)Please confirm the variability state
and absorption state of object
parts height .
2)On the situation that the
recognition of Ans47(30~36) is
error,It is judged that part of
electrode is float.Recognition
Option:Please confirm the set of
float permission.On the situation
that the recognition of Ans47(37) is
error,It is judged that all the
levelness of parts is
abnormal.Please confirm surface
adsorption state(whether the
adsorption state depended with
projection etc exists) of parts.
43046
2-1-3-82
NPM-TT2 EJM1EE-MB-02T-02
Parts Recognition Error
Parts Recognition Error
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 42
Error Code
Error Message
Cause Inspection and Solution
Invalid brightness of
detected electrode.
- Electrode brightness varies
too much or is insufficient
because of crushed balls
with ball array components
or bent leads with lead
array components.This
error also occurs if the
recognition option:
brightness check results
NG. (Ans47 (51) error code
applies.)
(Recognition error -
Electrode brightness error)
Take any of the following measures:
1) Check the position and size of
the electrodes of the registered
component shape.Make sure that
unstable shape on the image other
than the electrodes is not
registered.
2) Check the image status of the
electrode.If the electrode of the
array electrode components is
partly dark, adjust the lamp value
so that the brightness of the
electrode will be uniform.
3) In case of the recognition error of
Ans47(51), make sure the position
or level registered in the
brightness check option is correct.
43047
Bad mark was judged to be
present in bad mark
recognition.
(Recognition error -
Detection error in target
marks for judgment)
If this error occurs at the position
with no bad marks during bad mark
recognition, check the mark
judgment area size, setting lamp
value and image TH value.Presence
of mark cannot be determined
reliably when using an unstable
location in the image.Perform
teaching so that there may be
difference in image stable enough to
determine the presence of mark.
43049
2-1-3-83
NPM-TT2 EJM1EE-MB-02T-02
Rough Detect Error(0)
Picture contrast Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Failed to find threshold for
boundary detection.
(Insufficient dispensing error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43501
No pattern detected during
boundary detection.
(Insufficient dispensing error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43502
2-1-3-84