N7201A654E.pdf - 第174页
NPM- TT2 EJM1EE-MB-02 T-02 Safety Device Detec t (Post Proc) Safety Device Detec t (Pre Proc) Error Messag e Troubleshooting 2-1-4 Emergency stop errors 2 Error Code Error Message Cause Inspection and Solution Adjoining …

NPM-TT2 EJM1EE-MB-02T-02
Cover Open
(Rear Side Safety switch
this side)
Cover Open
(Front Side Safety switch
this side)
Error
Messag
e
Solutions to errors
Troubleshooting
2-1-4
Emergency stop errors 1
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1302
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1303
2-1-4-1

NPM-TT2 EJM1EE-MB-02T-02
Safety Device Detect
(Post Proc)
Safety Device Detect
(Pre Proc)
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 2
Error Code
Error Message
Cause Inspection and Solution
Adjoining machine in the
previous process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
previous process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
previous machine if pressed.
1304
Adjoining machine in the
next process has been
turned OFF or emergency
stop switch has been
pressed.
(Interlock occurred.)
Take any of the following measures:
1) Turn ON power if the main switch
of the adjoining machine in the
next process is OFF.
2) Reset the emergency stop switch
of the adjoining machine in the
next process machine if pressed.
1305
2-1-4-2

NPM-TT2 EJM1EE-MB-02T-02
Momentary Power OFF
Cover Open
(Rear Side Safety switch
interior side)
Cover Open
(Front Side Safety switch
interior side)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1306
Safety cover is open.
(Interlock occurred.)
Take measures in the following
order.
1) Close the safety cover if opened.
2) If the error persists even after the
safety cover is closed, the safety
switch may be at fault.Contact
PFSC.
1307
Power supply may have
been stopped momentarily
due to power failure.
(Interlock occurred.)
Check the voltage of the power
supply in the plant. Turn the
machine power back ON and start
production. If the error persists,
contact PFSC.
1308
2-1-4-3