N7201A654E.pdf - 第233页

NPM- TT2 EJM1EE-MB-02 T-02 Communication : Data Length Err or Communication : Hand Shake Error Communication : Communic ation Default Unconnected Er ror Communication : Head Communication Error Solutions to errors Error …

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
Communication: Head
Communication Part
Answer Error
Communication:
Command Enable Invalid
Error
Communication:
Semaphore Error
Communication: File Open
Error
Communication: Data
Write Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 31
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to write data.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1725
Improper procedure was
taken in software processing.
(Failed to open file.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1726
Improper procedure was
taken in software processing.
(Failed to control software.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1727
Improper procedure was
taken in software processing.
(Failed to disable enable
command.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1728
Interrupt occurred to get
module errors.
(Error in connection module
like head^ feeder cart or
tray.)
Take measures according to the
error information of the module that
issues error interruption.
1729
2-1-4-60
NPM-TT2 EJM1EE-MB-02T-02
Communication: Data
Length Error
Communication: Hand
Shake Error
Communication:
Communication Default
Unconnected Error
Communication: Head
Communication Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1730
Connection module
connected to the machine
failed to be detected.
(Communication error
occurred.)
Check the connection of the feeder
cart.
1731
Error occurred in
communication with the head
or feeder cart.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1732
Improper procedure was
taken in software processing.
(Invalid data length found in
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1733
2-1-4-61
NPM-TT2 EJM1EE-MB-02T-02
Communication: Received
Data Size Error
Communication: Argument
Pointer NULL Error
Communication: Complete
Interrupt Timeout
Communication:
Command Enabling
Timeout
Communication: Check
Sum Error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 32
Error Code
Error Message
Cause Inspection and Solution
Check sum error occurred in
the communication data from
the head or feeder cart to the
host.
(Communication error
occurred.)
Clean the drawer connectors for
connecting head and feeder cart,
and check the wiring to be
connected to them. If the error
persists, contact PFSC.
1734
Improper procedure was
taken in software processing.
(Improper procedure was
found in synchronization
process during head
communication.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1735
Improper procedure was
taken in software processing.
(Timeout error occurred in
completion interrupt.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1736
Improper procedure was
taken in software processing.
(Argument pointer is null.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1737
Improper procedure was
taken in software processing.
(Improper received data
size.)
Close the error screen and restart
production. Then, check the
situation of the error occurred and
error message, and contact PFSC.
1738
2-1-4-62