N7201A654E.pdf - 第290页
NPM- TT2 EJM1EE-MB-02 T-02 Nozz le Cha nge Error EMG state detect Invalid Mounted Points Error Messag e Troubleshooting 2-1-4 Emergency stop errors 60 Error Code Error Message Cause Inspection and Solution System may be …

NPM-TT2 EJM1EE-MB-02T-02
LNB barcode analysis
time out
LNB barcode analysis
error
LNB process error
Other Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Error with unanalyzable
cause occurred.
(Other error occurred.)
Turn OFF power once and restart
the machine. If the error persists,
contact PFSC.
2212
Error detected from LNB.
(LNB processing error
occurred.)
Check the situation of the error
occurred and error message, and
contact PFSC.
2220
LNB failed to analyze the
PCB barcode.
(LNB barcode analysis error
occurred.)
Take any of the following measures:
1) Check the PCB ID setting of LNB.
2) Check the PCB code setting of
DGS.
2221
Failed to obtain the result of
PCB barcode analysis from
LNB and timeout occurred.
(LNB barcode analysis
timeout error occurred.)
Take any of the following measures:
1) Check the PCB ID setting of LNB.
2) Check the PCB code setting of
DGS.
2222
2-1-4-117

NPM-TT2 EJM1EE-MB-02T-02
Nozzle Change Error
EMG state detect
Invalid Mounted Points
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 60
Error Code
Error Message
Cause Inspection and Solution
System may be at fault.
(Mismatch occurred in
mounting finished points.)
Contact PFSC.
2223
Any of the following causes
is likely:
1) Emergency stop switch
has been pressed.
2) Safety cover is open.
3) Opening sensor detected.
(Emergency stop status
detected.)
Eliminate the cause of emergency
stop and restart production.
2224
Any of the following causes
is likely:
1) Improper shutter action at
nozzle changer
2) Improper cylinder action
3) Deformed or bent nozzle
(Nozzle change error
occurred when measure the
cart height .)
Take measures shown with the
same number as that of the cause.
1) Choose [Machine]-[Adjust]-
[Head]-[Nozzle exchange] and
open/close the nozzle changer.
Check for proper movement. If
stopped or caught on the way,
perform cleaning.
2) Replace the cylinder.
3) Replace the nozzle.
2225
2-1-4-118

NPM-TT2 EJM1EE-MB-02T-02
Check error before axis
action
PartsDetectAfterMounting(
VLCOutputData out of
validRangeErr)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Return the output value
which exceeds allowable
range from VLC unit.
(Error occurred in parts
detect after mounting.)
1. Please confirm that there are no
parts dropped on the PCB.2. Please
confirm that there is no dust(Parts
etc.) on the setting side of nozzle
holder set in nozzle changer.3.
Please confirm there is no dust
adhered to VLC unit.4. If it can't be
solved by above 1,2,3, please
calibrate the VLC unit.
2226
According to the soft
process^ move to incorrect
position.
(Error has been detected in
the check before axis action.)
Please start the production again
after confirming the production PCB.
If the error persists, contact PFSC.
2227
2-1-4-119