N7201A654E.pdf - 第256页
NPM- TT2 EJM1EE-MB-02 T-02 IspBox SubSys Camera IF board error IspBox SubSys Communication error IspBox SubSys Communication error IspBox SubSys Abno rmal IspBox MainSys RPC communication error Error Messag e Troubleshoo…

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys Inspector
box initialization error
IspBox MainSys Hard disk
capacity not enough error
IspBox MainSys Make the
LNB work folder error
IspBox MainSys Machine
command Initialization
command error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Initial commands were sent
more than once from the
machine.
(Multiple initialization
commands received from
machine.)
Restart the machine.
1874
Work folder for LNB could
not be created.
(Failed to create LNB work
folder.)
Check the network connection. Then,
restart the machine.
1875
Hard disk space is
insufficient.
(Insufficient hard disk space)
Check the available hard disk space.
1876
Invalid head type
(Unsupported head type was
notified.)
After turning OFF the machine
power, check the mounted head. If
the error persists, contact PFSC.
1877
2-1-4-83

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Camera IF
board error
IspBox SubSys
Communication error
IspBox SubSys
Communication error
IspBox SubSys Abnormal
IspBox MainSys RPC
communication error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 43
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(RPC communication failed.)
Restart the machine. If the error
persists, contact PFSC.
1878
Improper procedure was
taken in software processing.
(Error occurred in sub
system.)
Restart the machine. If the error
persists, contact PFSC.
1879
Improper procedure was
taken in software processing.
(Process specified in
communication not found.)
Restart the machine. If the error
persists, contact PFSC.
1880
Improper procedure was
taken in software processing.
(Transmitted parameters not
correct.)
Restart the machine. If the error
persists, contact PFSC.
1881
Improper procedure was
taken in software processing.
(Failed to set configuration
data.)
Restart the machine. If the error
persists, contact PFSC.
1882
2-1-4-84

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Inspection
result data evolution error
IspBox SubSys Production
data Transfer error
IspBox SubSys Production
data View data error
IspBox SubSys Common
image memory ensure
error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to obtain the memory
for shared images.)
Restart the machine. If the error
persists, contact PFSC.
1883
View data in production data
could not be obtained
properly.
(Failed to obtain the view
data in production data.)
Optimize the production data.
1884
Improper procedure was
taken in software processing.
(Production data not
transferred to inspection sub
system.)
Restart the machine. If the error
persists, contact PFSC.
1885
Improper procedure was
taken in software processing.
(Inspection failed.)
Restart the machine. Then,
download the production data again.
1886
2-1-4-85