NPM- TT2 EJM1EE-MB-03 T-01 3-2-1 -9

100%1 / 332
NPM-TT2 EJM1EE-MB-03T-01
Solutions to
recognition
3-2-1-8
Code Description Cause Solution
46
Height (lifting) error of an electrode
or entire component
Error that arises upon confirmation
of a height abnormality by the 3D
sensor / Multi-recognition camera
(type 3).
1) Component error
2) Component data setting error
Check the target component
Check the component data
Shape data position, size and
height evaluation
47
Electrode unit brightness state error Error that arises when the
brightness state of aligned
electrodes is not even or that is
detected by brightness checking.
1) Component error (including
crushing of bumps)
2) Component data setting error
Check the target component
Check the component data
Shape data position, size and
brightness evaluation
48 Electrode or entire component
height (lifting) error
*ANS48(98) indicates
communication error with multi-
recognition camera Type 3 kit.
Error that arises only during 3D
recognition error using multi-
recognition camera type 2/type 3.
1) Component error
2) Component data setting error
3) Outside of specifications for
thickness or floating
measurement
Check the target component
Check the component data
Shape data position, size and
various float limits
Check if it is described in
specifications.
If you decide to quit 3D
recognition and perform only 2D
recognition, change “Camera
type” on DGS to “2D camera”.
*In case it still occurs, contact
us.
49
Evaluation target mark detection
error
1) If a bad mark has been detected
with the bad mark recognition.
2) If a mark is not found at a given
location by polarity mark
checking.
Check the target component
Check the component data
Brightness evaluation, polarity
checking
Other/Individual evaluation/ designated item errors
Other individual evaluation/designated item errors
NPM-TT2 EJM1EE-MB-03T-01
3-2-1-9
4 Load Arrangement