NPM- TT2 EJM1EE-MB-02 T-02 IspBox MainSys Machine communication error IspBox MainSys Machine communication error IspBox MainSys Production dat a Read error IspBox MainSys Machine command Command abnormal timing error Err…

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys
Production data Lot
information error
IspBox MainSys
Production data Parts
information error
IspBox MainSys Mark
correction Information
register error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to save mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1859
Check result data of the
component specified by the
machine does not exist.
(Production data (inspection
data) unmatched between
the machine and the
inspection box.)
Download the production data again.
1860
Lot data specified by the
machine does not exist.
(Lot data unmatched
between the machine and
the inspection box.)
Download the production data again.
1861
2-1-4-79

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys Machine
communication error
IspBox MainSys Machine
communication error
IspBox MainSys
Production data Read
error
IspBox MainSys Machine
command Command
abnormal timing error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 41
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Production-related
command was notified from
the machine when
production was not
ongoing.)
Take measures shown with the
same number as that of the cause.
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error persists even after the
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1862
Production data cannot be
loaded.
(Failed to read production
data.)
Check the production data.
1863
Improper procedure was
taken in software processing.
(Failed to transmit command
to machine.)
Restart the machine. If the error
persists, contact PFSC.
1864
Improper procedure was
taken in software processing.
(Failed to receive command
from machine.)
Restart the machine. If the error
persists, contact PFSC.
1865
2-1-4-80

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys Snsr
calibration Distortion
correction error
IspBox MainSys Snsr
calibration Light measure
error
IspBox MainSys Snsr
calibration Correction post
recog error
IspBox MainSys Whole
board image save error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Image could not be saved
properly.
(Failed to save the image.)
Check the available hard disk space.
1866
Calibration post could not be
recognized properly.
(Failed to recognize
calibration post.)
Clean the calibration post.
1867
Brightness of the jig could
not be measured properly.
(Failed to measure the
brightness of jig.)
Clean the jig.
1868
Distortion could not be
corrected properly.
(Failed to correct distortion.)
Clean the jig.
1869