N7201A654E.pdf - 第69页

NPM- TT2 EJM1EE-MB-02 T-02 LW16-Nozzle Head θ PCB Temper ature Erro r LW16-Nozzle Head θ PCB Voltage Error LW16-Nozzle Head Z PCB Fuse Disconne ction LW16-Nozzle Head Z PCB Temper ature Erro r LW16-nozzle head Z PCB Volt…

100%1 / 332
NPM-TT2 EJM1EE-MB-02T-02
PrePickup Insp comm err
There is no feeder cover
or tray feeder
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 22
Error Code
Error Message
Cause Inspection and Solution
No feeder cover. Or tray
feeder not installed.Or if it is
the tray feeder/exchange
cart switch specification^ the
settings of the sensor switch
section knob are
mismatching.
(Self-diagnosis error
occurred.)
Take any of the following measures:
1) Attach the feeder cover when the
feeder cart is used.
2) When the tray feeder is used,
install the tray feeder and then
insert the key in the tray feeder
detection switch.
3) If it is the tray feeder/exchange
cart switch specification, please
match the settings of the sensor
switch section knob.
4) If the error persists, choose
[Machine] - [Adjust] - [All] - [Input
confirm] and check that the feeder
cover is attached and the tray
detection switch is connected.
40138
The communication state is
abnormal among MC-LNB-
ISS(Inspection Server
Software).
(Self-diagnosis error
occurred.)
Take any of the following measures:
1)Please confirm the
communication state between MC
and LNB, LNB and ISS.
2)Please confirm state or setting of
LNB and ISS.
40157
2-1-2-43
NPM-TT2 EJM1EE-MB-02T-02
LW16-Nozzle HeadθPCB
Temperature Error
LW16-Nozzle HeadθPCB
Voltage Error
LW16-Nozzle Head Z PCB
Fuse Disconnection
LW16-Nozzle Head Z PCB
Temperature Error
LW16-nozzle head Z PCB
Voltage Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Voltage at the LW16-nozzle
mount head Z-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40158
CPU temperature at the
LW16-nozzle mount head Z-
axis control board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40159
Fuse of the LW16-nozzle
mount head Z-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40160
Voltage at the LW16-nozzle
mount head θ-axis control
board has dropped
abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40161
CPU temperature at the
LW16-nozzle mount head θ-
axis control board has
exceeded the setting value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40162
2-1-2-44
NPM-TT2 EJM1EE-MB-02T-02
Multi Recog Camera FAN
alarm
Multi Recog Cam
temperature warning
Multi Recog Cam voltage
warning
LW16-Nozzle HeadθPCB
Fuse Disconnection
Error
Messag
e
Troubleshooting
2-1-2
Self-diagnosis errors 23
Error Code
Error Message
Cause Inspection and Solution
Fuse of the LW16-nozzle
mount head θ-axis control
board has blown.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40163
Voltage at the multi recog
camera control board has
dropped abnormally.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the voltage, and contact PFSC.
40164
CPU temperature at the multi
recog camera control board
has exceeded the setting
value.
(Self-diagnosis error
occurred.)
Choose [Machine] - [Information] -
[Firmware] - [Information] to check
the temperature, and contact PFSC.
40165
Fan of the multi recog
camera stopped.
(Self-diagnosis error
occurred.)
Because obstacle interfere with the
fan of multi recognition camera
inside or the fan at fault, please
contact PFSC.
40166
2-1-2-45