NPM-TT2 EJM1EE-MB-02T-02
Support Plate Position
Error
(Right)
Support Plate Position
Error
(Left)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
The support plate has not
lowered completely.
(Interlock occurred.)
Take any of the following measures:
1) Check the grease condition of the
up/down shaft.
2) Remove any foreign body
between the table and machine
base.If the error persists, the
sensor may be displaced or at fault.
Contact PFSC.
1322
The support plate has not
lowered completely.
(Interlock occurred.)
Take any of the following measures:
1) Check the grease condition of the
up/down shaft.
2) Remove any foreign body
between the table and machine
base.If the error persists, the
sensor may be displaced or at fault.
Contact PFSC.
1323
2-1-4-13
NPM-TT2 EJM1EE-MB-02T-02
Nozzle Interference Area
Intrusion
(Rear Side Front Row)
Nozzle Interference Area
Intrusion
(Front Side Rear Row)
Nozzle Interference Area
Intrusion
(Front Side Front Row)
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 8
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Z-axis interference sensor
may be at fault or sensor
cable may be broken.
2) Y-axis interference sensor
may be at fault or sensor
cable may be broken.
(Interlock occurred.)
Choose [Machine] - [Adjust] - [All] -
[Input confirm] and if any problem is
found, contact PFSC.
1324
Any of the following causes
is likely:
1) Z-axis interference sensor
may be at fault or sensor
cable may be broken.
2) Y-axis interference sensor
may be at fault or sensor
cable may be broken.
(Interlock occurred.)
Choose [Machine] - [Adjust] - [All] -
[Input confirm] and if any problem is
found, contact PFSC.
1325
Any of the following causes
is likely:
1) Z-axis interference sensor
may be at fault or sensor
cable may be broken.
2) Y-axis interference sensor
may be at fault or sensor
cable may be broken.
(Interlock occurred.)
Choose [Machine] - [Adjust] - [All] -
[Input confirm] and if any problem is
found, contact PFSC.
1326
2-1-4-14
NPM-TT2 EJM1EE-MB-02T-02
Servo Amplifier
Abnormality
(Rear X axis)
Servo Amplifier
Abnormality
(Front Y axis)
Servo Amplifier
Abnormality
(Front X axis)
Nozzle Interference Area
Intrusion
(Rear Side Rear Row)
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Z-axis interference sensor
may be at fault or sensor
cable may be broken.
2) Y-axis interference sensor
may be at fault or sensor
cable may be broken.
(Interlock occurred.)
Choose [Machine] - [Adjust] - [All] -
[Input confirm] and if any problem is
found, contact PFSC.
1327
Servo driver is at fault.
(Interlock occurred.)
1) Make sure there is no obstacle to
the XY unit and restart the
machine.
2) If the error persists, contact
PFSC.
1328
Servo driver is at fault.
(Interlock occurred.)
1) Make sure there is no obstacle to
the XY unit and restart the
machine.
2) If the error persists, contact
PFSC.
1329
Servo driver is at fault.
(Interlock occurred.)
1) Make sure there is no obstacle to
the XY unit and restart the
machine.
2) If the error persists, contact
PFSC.
1330
2-1-4-15