NPM- TT2 EJM1EE-MB-02 T-02 IspBox MainSys Production data View information error IspBox MainSys Production start error IspBox MainSys Busy error IspBox MainSys Inspection re sult make error Error Messag e Troubleshooting…

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys
Inspection result use
memory ensure error
IspBox MainSys
Production data Read
unfinished error
IspBox MainSys Machine
command Undefined error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Any of the following causes
is likely:
1) Improper procedure was
taken in software
processing.
2) Mismatch of the software
version between the
machine and the inspection
box.
(Undefined command
notified from machine to
inspection box.)
Take any of the following measures:
1) Restart the machine. If the error
persists, contact PFSC.
2) If the error occurred after
upgrade, check the situation of the
error occurred and error message,
and contact PFSC.
1852
Improper procedure was
taken in software processing.
(Inspection box has not
loaded production data.)
Restart the machine. If the error
persists, contact PFSC.
1853
Improper procedure was
taken in software processing.
(Failed to secure memory for
saving inspection results.)
Restart the machine. If the error
persists, contact PFSC.
1854
2-1-4-77

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys
Production data View
information error
IspBox MainSys
Production start error
IspBox MainSys Busy
error
IspBox MainSys
Inspection result make
error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 40
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to create the
inspection result data.)
Restart the machine. If the error
persists, contact PFSC.
1855
Improper procedure was
taken in software processing.
(Next command cannot be
executed because current
command is in execution.)
Restart the machine. If the error
persists, contact PFSC.
1856
Production start command
was notified in mode other
than preparation.
(Production cannot be
started.)
Select the preparation mode.
1857
View data specified by
machine does not exist.
(View data unmatched
between the production data
in the machine and that
loaded by the inspection
box.)
Download the production data again.
1858
2-1-4-78

NPM-TT2 EJM1EE-MB-02T-02
IspBox MainSys
Production data Lot
information error
IspBox MainSys
Production data Parts
information error
IspBox MainSys Mark
correction Information
register error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to save mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1859
Check result data of the
component specified by the
machine does not exist.
(Production data (inspection
data) unmatched between
the machine and the
inspection box.)
Download the production data again.
1860
Lot data specified by the
machine does not exist.
(Lot data unmatched
between the machine and
the inspection box.)
Download the production data again.
1861
2-1-4-79