N7201A654E.pdf - 第157页
NPM- TT2 EJM1EE-MB-02 T-02 Down Lead Check Error Fly Pattern Check Error Solutions to errors Error Code Error Message Cause Inspection and Solution Skipped patter n detected in skip ped pattern c heck. (Inspection error …

NPM-TT2 EJM1EE-MB-02T-02
Nozzle Stuffed Check
Error
Rough Detect Error(1)
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 43
Error Code
Error Message
Cause Inspection and Solution
No pattern detected after
removing noise or skipped
pattern.
(Insufficient dispensing error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43503
No pattern found in more
than one point of multiple
nozzles in clogged nozzle
check.
(Clogged nozzle error
occurred during priming shot
recognition.)
Take any of the following measures:
1) Execute eject check by
dispensing the material forcibly.
2) Check the nozzle in use.
3) Perform priming shot teaching
and check the shot condition.
4) Correct the parameter(s) that
caused the error.
43504
2-1-3-85

NPM-TT2 EJM1EE-MB-02T-02
Down Lead Check Error
Fly Pattern Check Error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Skipped pattern detected in
skipped pattern check.
(Inspection error occurred
during priming shot
recognition. )
Take any of the following measures:
1) Perform priming shot teaching
and check the shot condition.
2) Correct the parameter(s) that
caused the error. Lower the setting
temperature of adhesive to reduce
adhesive scattering.
43505
Cobwebbing detected in
cobwebbing check.
(Inspection error occurred
during priming shot
recognition. )
Take any of the following measures:
1) Perform priming shot teaching
and check the shot condition.
2) Correct the parameter(s) that
caused the error. Increase the
setting value at the head rising
position to heighten the pull-up
height of the nozzle. Raise the
setting temperature of adhesive to
reduce cobwebbing.
43506
2-1-3-86

NPM-TT2 EJM1EE-MB-02T-02
Recog Param Error
(Pixel Rate)
Area Rate Check Error
Total Area Check Error
Error
Messag
e
Troubleshooting
2-1-3
Single stop errors 44
Error Code
Error Message
Cause Inspection and Solution
Total dot area size are
detected abnormal.
(Inspection error occurred
during priming shot
recognition. )
Take any of the following measures:
1) Perform priming shot teaching
and check the shot condition. The
reference value of the area can be
taught.
2) Correct the parameter(s) that
caused the error. Adjust the
dispensing time and reference
area value.
43507
Proportion between large dot
size and small dot size is
abnormal in the area check.
(Inspection error occurred
during priming shot
recognition. )
Take any of the following measures:
1) Clean the nozzle in use.
2) Perform priming shot teaching
and check the shot condition.
3) Correct the parameter(s) that
caused the error.
43508
Abnormal pixel rate of head
camera.
(Recognition parameter error
(pixel rate) occurred.)
Check the pixel rate of the head
camera. If the error persists, contact
PFSC.
43509
2-1-3-87