N7201A654E.pdf - 第258页
NPM- TT2 EJM1EE-MB-02 T-02 IspBox SubSys Sample inspection err or IspBox SubSys In spection result data Memory abnormal IspBox SubSys In spection process interrupt IspBox SubSys Image data Unma tched error Error Messag e…

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Inspection
result data evolution error
IspBox SubSys Production
data Transfer error
IspBox SubSys Production
data View data error
IspBox SubSys Common
image memory ensure
error
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Failed to obtain the memory
for shared images.)
Restart the machine. If the error
persists, contact PFSC.
1883
View data in production data
could not be obtained
properly.
(Failed to obtain the view
data in production data.)
Optimize the production data.
1884
Improper procedure was
taken in software processing.
(Production data not
transferred to inspection sub
system.)
Restart the machine. If the error
persists, contact PFSC.
1885
Improper procedure was
taken in software processing.
(Inspection failed.)
Restart the machine. Then,
download the production data again.
1886
2-1-4-85

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Sample
inspection error
IspBox SubSys Inspection
result data Memory
abnormal
IspBox SubSys Inspection
process interrupt
IspBox SubSys Image
data Unmatched error
Error
Messag
e
Troubleshooting
2-1-4
Emergency stop errors 44
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Necessary image to be
loaded not found in the
view.)
Load the entire PCB image again.
1887
Inspection process was
stopped.
(Inspection process was
interrupted.)
Cancel stopping and resume the
process.
1888
Improper procedure was
taken in software processing.
(Insufficient memory space
of result data.)
Restart the machine. If the error
persists, contact PFSC.
1889
Improper procedure was
taken in software processing.
(Failed to inspect the sample
image.)
Restart the machine. If the error
persists, contact PFSC.
1890
2-1-4-86

NPM-TT2 EJM1EE-MB-02T-02
IspBox SubSys Production
data not evolved error
IspBox SubSys Production
data evolution error
IspBox SubSys Mark
correction error
IspBox SubSys Inspection
template data make error
IspBox SubSys State
abnormal
Solutions to errors
Error Code
Error Message
Cause Inspection and Solution
Improper procedure was
taken in software processing.
(Application condition is
abnormal.)
Restart the machine. If the error
persists, contact PFSC.
1891
Improper procedure was
taken in software processing.
(Failed to create inspection
template data.)
Restart the machine. If the error
persists, contact PFSC.
1892
Improper procedure was
taken in software processing.
(Failed to register mark result
information.)
Restart the machine. If the error
persists, contact PFSC.
1893
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1894
Improper procedure was
taken in software processing.
(Inspection box system error
occurred.)
Restart the machine. If the error
persists, contact PFSC.
1895
2-1-4-87